Target error evaluation of a minimal invasive cochlear implant strategy using a patient specific miniature stereotactical frame

نویسندگان

  • Samuel John
  • Thomas S. Rau
  • G. Jakob Lexow
  • Thomas Lenarz
  • Omid Majdani
چکیده

Minimally invasive cochlear implant surgeries require a very high accuracy of at least 0.5 mm when drilling a canal through the most critical spot, the facial recess [1]. Important anatomical structures in the vicinity of the minimal invasive access path, including the facial nerve and the chorda tympani must be preserved. We conducted a quantitative verification study on five temporal bone specimens using the patient specific miniature stereotactical frame called „Microtable“. The Microtable is developed at Vanderbilt University (Nashville, TN) and evaluated in a multi center study together with the Medical School Hannover (MHH). After classical mastoidectomy and opening of the facial recess we measured the target error at the facial recess in an extra „post-OP“ CBCT (Cone Beam Computed Tomography) scan with a sham drill bit inserted.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Cochlear Implant

The studies on cochlear implants have been conducted in the United States, Austria, Brasil, France, Finland, and some other countries. Up to now, this technique does not seem to have a wide spread application. Indeed it can only apply cases of deafness still presenting sufficient neural remnants to transmit the message. Moreover, the patient must be totally deaf( quasi­ complete loss of har cel...

متن کامل

Clinical Determination of Target Registration Error of an Image- Guided Otologic Surgical System using Patients with Bone-Anchored Hearing Aids

Image guidance in otologic surgery has been thwarted by the need for a non-invasive fiducial system with target registration error (TRE) at the inner ear below 1.5mm. We previously presented a fiducial frame for this purpose that attaches to the upper dentition via patient-specific bite blocks and demonstrated a TRE of 0.73mm (±0.23mm) on cadaveric skulls. In that study, TRE measurement depende...

متن کامل

Evaluation of Saccular Function Pre-Post Cochlear Implant Surgery Using VEMPs

Objectives: The aim of present study was evaluation of saccule function in cochlear implant candidates with severe to profound sensory neural hearing loss Before and after cochlear implantation Methods: In this study 35 cochlear implant (CI) candidates with bilateral severe to profound sensory neural hearing loss before and about 30 days after cochlear implant and 20 normal-hearing cases as ...

متن کامل

Evaluation of the Slope of Amplitude Growth Function Changes of the Electrically Evoked Action Potential in Three Months after Receiving the Device in Children with Cochlear Implant

Objective: In neural response telemetry, intracochlear electrodes stimulate the auditory nerve and record the neural responses. The electrical stimulation is sent to the auditory nerve by an electrode and the resulted response, called electrically evoked compound action potential, is recorded by an adjacent electrode. The most important clinical applications of this test are evaluation and moni...

متن کامل

Investigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation evaluated by CT-Scan

Background Cochlear implant surgery is an invasive procedure for patients with bilateral Sensorineural hearing loss and may cause some risks such as cochlear damage. We aimed to evaluate the effectiveness of cochlear measures obtained by computed tomography (CT) scan in predicting depth of cochlear implant insertion. Materials and Methods This study was conducted in a retrospective and cross-se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013