Methemoglobin in blood as determined by double-wavelength spectrophotometry.

نویسندگان

  • M Sakata
  • A Yoshida
  • M Haga
چکیده

We describe spectrophotometric determination of methemoglobin (Met-Hb) in blood by absorbance differences at two wavelengths (characteristic of the instrument used) in the 500-600 nm region. Blood is diluted 100- to 200-fold with a solution containing KCN and carbon monoxide to convert hemoglobin to carboxyhemoglobin and Met-Hb to cyanomethemoglobin (CN-Met-Hb). Carboxyhemoglobin has the same absorbance at the two wavelengths used, so that the differences in absorbance reflect only the CN-Met-Hb component. After measurement of absorbance differences, potassium ferricyanide is added to convert all hemoglobin derivatives to CN-Met-Hb; samples are then remeasured at the same wavelengths. The percentage of Met-Hb is determined from the ratio of the absorbance differences. Results agree satisfactorily with currently accepted procedures and with calculated theoretical results for mixtures of oxyhemoglobin, carboxyhemoglobin, and Met-Hb.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determining methemoglobin in blood by zero-crossing-point first-derivative spectrophotometry.

We determined methemoglobin in blood by zero-crossing-point first-derivative spectrophotometry. After lysis of erythrocytes, hemoglobin was converted into oxyhemoglobin and the first derivative spectrum was recorded between 405 and 425 nm. At the exact point where the first-derivative spectrum of oxyhemoglobin was zero ("zero-crossing point"), the first-derivative value of oxyhemoglobin and met...

متن کامل

New method for rapid determination of carboxyhemoglobin by use of double-wavelength spectrophotometry.

We have developed a simple method for rapid determination of carboxyhemoglobin concentration in blood, by use of double-wavelength spectrophotometry. The absorbance of both oxyhemoglobin and reduced hemoglobin are instrumentally nulled out in this procedure, so that the absorption signal reflects HbCO and only a single spectrophotometric reading is required. This procedure is accurate in the ra...

متن کامل

Recent trends in designer drug abuse.

Methemoglobin, myoglobin, and methemalbumin can cause abnormal dark color in patient samples. “Lipemia” was measured at 660and 700-nm wavelengths (1 ); therefore any compounds that absorb light in this range will result in an increased lipemic index. In this patient, methemoglobin was always 7.5% (cooximetry), myoglobin was not detected (gel filtration chromatography and mass spectrometry), but...

متن کامل

Optimal Wavelength Selection in Ultraviolet Spectroscopy for the Estimation of Toxin Reduction Ratio during Hemodialysis

Introduction The concentration of substances, including urea, creatinine, and uric acid, can be used as an index to measure toxic uremic solutes in the blood during dialysis and interdialytic intervals. The on-line monitoring of toxin concentration allows for the clearance measurement of some low-molecular-weight solutes at any time during hemodialysis.The aim of this study was to determine the...

متن کامل

Antioxidant effect of different vitamins on methemoglobin production: An in vitro study

Nitrite intoxication occurs frequently in ruminants and equines. The most common treatment of this disorder is administration of 1% methylene blue, although the use of some antioxidant agents e.g. vitamins and complementary treatment may also be useful. The aim of this study was to evaluate the in vitro antioxidative effects of some vitamins on methemoglobinemia induced by sodium nitrite. For t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 28 3  شماره 

صفحات  -

تاریخ انتشار 1982