Estimation of body fat in adults using a portable A-mode ultrasound.
نویسندگان
چکیده
OBJECTIVE This study aimed to develop and validate equations to estimate body fat based on anthropometric measurements of subcutaneous fat thickness (SFT) and muscle thickness (MT) measured by A-mode ultrasound (BodyMetrix) in Brazilian adults. METHODS Individuals (n = 206) underwent air-displacement plethysmography for body composition assessment. Arm, thigh, and calf circumferences were also obtained. SFT from triceps, biceps, subscapular, abdominal, thigh, and calf regions and MT from triceps, biceps, thigh, and calf regions were measured by BodyMetrix. Prediction equations were developed by stepwise multiple linear regression using the circumferences, weight, height, SFT, and MT. Lin's concordance correlation coefficient, mean difference, and 95% limits of agreement (95% LOA) were assessed in apparent and internal validity. RESULTS The prediction equation for whole-body fat for men included thigh circumference, triceps and thigh SFT, biceps MT, weight, and height. The equation for women included age, calf circumference, abdominal and calf SFT, weight, and height. The prediction equation overestimated men's whole-body fat by 0.5 percentual points, in average, and the lower and upper 95% LOA were -6.8% and 7.7%, respectively. For women, the prediction equation overestimated whole-body fat by 0.1 percentual points, in average. Lower and upper 95% LOA were -6.5% and 6.7%, respectively. Optimism-adjusted results using 500 repetitions with same size samples have shown similar results. Body fat extremes did not influence the whole-body fat estimation. CONCLUSIONS BodyMetrix A-mode ultrasound, in association with selected conventional anthropometric measurements, proved to be a reliable tool for the estimation of body fat percentage.
منابع مشابه
Application of a Sub-set of Skinfold Sites for Ultrasound Measurement of Subcutaneous Adiposity and Percentage Body Fat Estimation in Athletes.
Body composition assessment is an integral feature of elite sport as optimization facilitates successful performance. This study aims to refine the use of B-mode ultrasound in the assessment of athlete body composition by determining suitable sites for measurement. 67 elite athletes recruited from the Human Performance Laboratory, University College Cork, Ireland, underwent dual measurement of ...
متن کاملComparison of Total Fat, Percentage of Fat, Trunk Fat, Soft Lean and Mass Waist-Hip Ratio between Diabetic type II and Matched Non-Diabetic Iranians using Bioelectrical Impedance Analysis
Introduction: Research shows a relationship between diabetes (type II) and obesity. Bioelectrical Impedance Analysis (BIA) is a relatively new and approved method for the measurement of body composition. The aim of this study was to compare diabetic and non-diabetic adults on the basis of waist-hip ratio, total fat, percentage of fat, trunk fat, and soft lean mass. Methods: In this cross-sec...
متن کاملReproducibility and Validity of A-Mode Ultrasound for Body Composition Measurement and Classification in Overweight and Obese Men and Women
UNLABELLED Identifying portable methods to measure body composition may be more advantageous than using body mass index (BMI) to categorize associated health consequences. PURPOSE To compare the validity and reliability of a portable A-mode ultrasound (US) to a criterion three compartment model (3C) for the measurement of body composition. METHODS Forty-seven overweight and obese subjects p...
متن کاملFood Consumption and Anthropometric Assessment Survey of Autism Affected Children, Adolescents and, Adults: A Pilot Study
Background: Autism spectrum disorder (ASD) is referred to a group of complex neuro-developmental disorders, which can be characterized by impairments in social and communication skills as well as repetitive body movements and behaviors. The objective of this study was to examine adequacy of nutrient intake and to determine the scientific nutritional data of ASD individual. Methods: In this cros...
متن کاملBody Fat Mass Assessment: A Comparison between an Ultrasound-Based Device and a Discovery A Model of DXA
Objective. To examine measurement of body composition by ultrasound compared with a reference technique:dual energy X-ray absorptiometry (DXA). We evaluated the accuracy of a portable ultrasound-based device in estimating total body fat mass with those assessed by DXA in adult. Methods. Body fat mass has been estimated using a portable ultrasound-based device in comparison with a contemporary r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Nutrition
دوره 32 4 شماره
صفحات -
تاریخ انتشار 2016