Estimability index for volume quantification of homogeneous spherical lesions in computed tomography.

نویسندگان

  • Ehsan Samei
  • Marthony Robins
  • Baiyu Chen
  • Greeshma Agasthya
چکیده

Volume of lung nodules is an important biomarker, quantifiable from computed tomography (CT) images. The usefulness of volume quantification, however, depends on the precision of quantification. Experimental assessment of precision is time consuming. A mathematical estimability model was used to assess the quantification precision of CT nodule volumetry in terms of an index ([Formula: see text]), incorporating image noise and resolution, nodule properties, and segmentation software. The noise and resolution were characterized in terms of noise power spectrum and task transfer function. The nodule properties and segmentation algorithm were modeled in terms of a task function and a template function, respectively. The [Formula: see text] values were benchmarked against experimentally acquired precision values from an anthropomorphic chest phantom across 54 acquisition protocols, 2 nodule sizes, and 2 volume segmentation softwares. [Formula: see text] exhibited correlation with experimental precision across nodule sizes and acquisition protocols but dependence on segmentation software. Compared to the assessment of empirical precision, which required [Formula: see text] to perform the segmentation, the [Formula: see text] method required [Formula: see text] from data collection to mathematical computation. A mathematical modeling of volume quantification provides efficient prediction of quantitative performance. It establishes a method to verify quantitative compliance and to optimize clinical protocols for chest CT volumetry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran

Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...

متن کامل

Parametric investigation of autofrettage process in thick spherical vessel made of functionally graded materials

In this paper, the effect of autofrettage process parameters on the ultimate pressure that functionally graded spherical vessel can tolerate are investigated. FGM properties and autofrettage pressure are considered as important parameters. Assumptions are variation of properties of FGM in radial direction, the residual stress in the absence of Bauschinger effect with the operation of variable m...

متن کامل

Computed Tomography in the Diagnosis of Lesions in and Around the Saddle Area

Computed tomography is the method of choice for initial evaluation of pa tints with potential suprasellar masses. In our ex­perience during the last 2 years C.T. has proved reliable for detecting or rulling out the presence of a suprasellar mass.  It shows the direction and degree of parasellar extension and the presence of any calcific or cystic component of the le­sion. When C.T. was negat...

متن کامل

Utility of 123I-MIBG Standardized Uptake Value in Patients with Refractory Pheochromocytoma and Paraganglioma

Objective(s): Single-photon emission computed tomography (SPECT) using metaiodobenzylguanidine (MIBG) is an important diagnostic tool for the treatment of refractory pheochromocytoma and paraganglioma (PPGL). Owing to the difficulty of SPECT quantification, the tumour-to-background ratio (TBR) is used to assess disease activity. However, the utility of TBR is limited o...

متن کامل

Respiratory motion correction in prostate cancer positron emission tomography: A study on patients and phantom simulation

Introduction: To investigate the effects of breathing cycle and tree diaphragm motions on prostate cancer tumors standard uptake value (SUV) during positron emission tomography (PET) and to correct it. Materials and methods: Respiratory motion traces were simulated on the common patient breathing cycle and tree diaphragm motio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of medical imaging

دوره 5 3  شماره 

صفحات  -

تاریخ انتشار 2018