Importance of material model in wall stress prediction in abdominal aortic aneurysms.
نویسندگان
چکیده
BACKGROUND Results of biomechanical simulation of the abdominal aortic aneurysm (AAA) depend on the constitutive description of the wall. Based on in vitro and in vivo experimental data several constitutive models for the AAA wall have been proposed in the literature. Those models differ strongly from each other and their impact on the computed stress in biomechanical simulation is not clearly understood. METHODS Finite element (FE) models of AAAs from 7 patients who underwent elective surgical repair were used to compute wall stresses. AAA geometry was reconstructed from CT angiography (CT-A) data and patient-specific (PS) constitutive descriptions of the wall were derived from planar biaxial testing of anterior wall tissue samples. In total 28 FE models were used, where the wall was described by either patient-specific or previously reported study-average properties. This data was derived from either uniaxial or biaxial in vitro testing. Computed wall stress fields were compared on node-by-node basis. RESULTS Different constitutive models for the AAA wall cause significantly different predictions of wall stress. While study-average data from biaxial testing gives globally the same stress field as the patient-specific wall properties, the material model based on uniaxial test data overestimates the wall stress on average by 30 kPa or about 67% of the mean stress. A quasi-linear description based on the in vivo measured distensibility of the AAA wall leads to a completely altered stress field and overestimates the wall stress by about 75 kPa or about 167% of the mean stress. CONCLUSION The present study demonstrated that the constitutive description of the wall is crucial for AAA wall stress prediction. Consequently, results obtained using different models should not be mutually compared unless different stress gradients across the wall are not taken into account. Highly nonlinear material models should be preferred when the response of AAA to increased blood pressure is investigated, while the quasi-linear model with high initial stiffness produces negligible stress gradients across the wall and thus, it is more appropriate when response to mean blood pressure is calculated.
منابع مشابه
Importance of initial aortic properties on the evolving regional anisotropy, stiffness and wall thickness of human abdominal aortic aneurysms.
Complementary advances in medical imaging, vascular biology and biomechanics promise to enable computational modelling of abdominal aortic aneurysms to play increasingly important roles in clinical decision processes. Using a finite-element-based growth and remodelling model of evolving aneurysm geometry and material properties, we show that regional variations in material anisotropy, stiffness...
متن کاملDrug Therapy for Small Abdominal Aortic Aneurysm
Dear Editor,Abdominal aortic aneurysm is often asymptomatic, less recognized, and causes considerable mortality and morbidity, if missed. The incidence varies from country to country and the occurrence is influenced by modifiable (smoking, coronary heart disease, hypertension, dyslipidemia, and prolonged steroid therapy) and non-modifiable risk factors (increasing age, male gender, and positive...
متن کاملA comparison of modelling techniques for computing wall stress in abdominal aortic aneurysms
BACKGROUND Aneurysms, in particular abdominal aortic aneurysms (AAA), form a significant portion of cardiovascular related deaths. There is much debate as to the most suitable tool for rupture prediction and interventional surgery of AAAs, and currently maximum diameter is used clinically as the determining factor for surgical intervention. Stress analysis techniques, such as finite element ana...
متن کاملBlood flow in abdominal aortic aneurysms: pulsatile flow hemodynamics.
Numerical predictions of blood flow patterns and hemodynamic stresses in Abdominal Aortic Aneurysms (AAAs) are performed in a two-aneurysm, axisymmetric, rigid wall model using the spectral element method. Physiologically realistic aortic blood flow is simulated under pulsatile conditions for the range of time-averaged Reynolds numbers 50< or =Re(m)< or =300, corresponding to a range of peak Re...
متن کاملFlow-induced wall shear stress in abdominal aortic aneurysms: Part II--pulsatile flow hemodynamics.
In continuing the investigation of AAA hemodynamics, unsteady flow-induced stresses are presented for pulsatile blood flow through the double-aneurysm model described in Part I. Physiologically realistic aortic blood flow is simulated under pulsatile conditions for the range of time-average Reynolds numbers 50< or =Re(m) < or =300. Hemodynamic disturbance is evaluated for a modified set of indi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical engineering & physics
دوره 35 9 شماره
صفحات -
تاریخ انتشار 2013