Exploring the capability of wireless near infrared spectroscopy as a portable seizure detection device for epilepsy patients

نویسندگان

  • Jesper Jeppesen
  • Sándor Beniczky
  • Peter Johansen
  • Per Sidenius
  • Anders Fuglsang-Frederiksen
چکیده

PURPOSE Near infrared spectroscopy (NIRS) has proved useful in measuring significant hemodynamic changes in the brain during epileptic seizures. The advance of NIRS-technology into wireless and portable devices raises the possibility of using the NIRS-technology for portable seizure detection. METHODS This study used NIRS to measure changes in oxygenated (HbO), deoxygenated (HbR), and total hemoglobin (HbT) at left and right side of the frontal lobe in 33 patients with epilepsy undergoing long-term video-EEG monitoring. Fifteen patients had 34 focal seizures (20 temporal-, 11 frontal-, 2 parietal-lobe, one unspecific) recorded and analyzed with NIRS. Twelve parameters consisting of maximum increase and decrease changes of HbO, HbR and HbT during seizures (1 min before- to 3 min after seizure-onset) for left and right side, were compared with the patients' own non-seizure periods (a 2-h period and a 30-min exercise-period). In both non-seizure periods 4 min moving windows with maximum overlapping were applied to find non-seizure maxima of the 12 parameters. Detection was defined as positive when seizure maximum change exceeded non-seizure maximum change. RESULTS When analyzing the 12 parameters separately the positive seizure detection was in the range of 6-24%. The increase in hemodynamics was in general better at detecting seizures (15-24%) than the decrease in hemodynamics (6-18%) (P=0.02). CONCLUSION NIRS did not seem to be a suitable technology for generic seizure detection given the device, settings, and methods used in this study. There are still several challenges to overcome before the NIRS-technology can be used as a home-monitoring seizure detection device.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Erratum to “Exploring the capability of wireless near infrared spectroscopy as a portable seizure detection device for epilepsy patients” [Seizure 26 (2015) 43–48]

Jesper Jeppesen *, Sándor Beniczky , Peter Johansen , Per Sidenius , Anders Fuglsang-Frederiksen a Department of Neurophysiology, Aarhus University Hospital, Nørrebrogade 44, 8000 Aarhus C, Denmark Department of Clinical Neurophysiology, Danish Epilepsy Centre, Visby Álle 5, 4293 Dianalund, Denmark Department of Engineering, Aarhus University, Finlandsgade 22, 8200 Aarhus N, Denmark Department ...

متن کامل

Correlation of intraoperative renal near infrared spectroscopy with the development of acute kidney injury in adult patients undergoing cardiac surgery using cardiopulmonary bypass

Introduction: The present study aimed to correlate renal oximetry near-infrared spectroscopy (NIRS) values with conventional non-invasive biomarkers for the early detection of acute kidney injury (AKI) in adult patients undergoing cardiac surgery using cardiopulmonary bypass (CPB). Accordingly, renal NIRS can be employed as a trending device for the prevention of AKI developmen...

متن کامل

Novel Application of Near-infrared Spectroscopy and Chemometrics Approach for Detection of Lime Juice Adulteration

The aim of this study is to investigate the novel application of a ‎handheld near infra-red spectrophotometer coupled with classification methodologies as a screening approach in detection of adulterated lime juices. For this purpose, a miniaturized near infra-red spectrophotometer (Tellspec®) in the spectral range of 900–1700 nm was used. Three diffuse reflectance spectra of 31 pure...

متن کامل

Novel Application of Near-infrared Spectroscopy and Chemometrics Approach for Detection of Lime Juice Adulteration

The aim of this study is to investigate the novel application of a ‎handheld near infra-red spectrophotometer coupled with classification methodologies as a screening approach in detection of adulterated lime juices. For this purpose, a miniaturized near infra-red spectrophotometer (Tellspec®) in the spectral range of 900–1700 nm was used. Three diffuse reflectance spectra of 31 pure...

متن کامل

Nondestructive Firmness Estimation of Tomato Fruit Using Near-Infrared Spectroscopy

Today, nondestructive methods are widely used to determine the quality of agricultural products. Meanwhile, visible and near-infrared (Vis/NIR) spectroscopy is regarded as one of the most widely used methods in the field of quality assessment of agricultural products. In this study, a system was developed to measure the Vis/NIR spectra of tomato fruit samples in the half-transmittance mode of m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Seizure

دوره 26  شماره 

صفحات  -

تاریخ انتشار 2015