Value of Image Fusion in Coronary Angiography for the Detection of Coronary Artery Bypass Grafts

نویسندگان

  • Julien Plessis
  • Karine Warin Fresse
  • Zachary Cahouch
  • Thibaut Manigold
  • Vincent Letocart
  • Laurianne Le Gloan
  • Béatrice Guyomarch
  • Patrice Guerin
چکیده

BACKGROUND Coronary angiography is more complex in patients with coronary artery bypass grafts (CABG). Image fusion is a new technology that allows the overlay of a computed tomography (CT) three-dimension (3D) model with fluoroscopic images in real time. METHODS AND RESULTS This single-center prospective study included 66 previous CABG patients undergoing coronary and bypass graft angiography. Image fusion coronary angiographies (fusion group, 20 patients) were compared to conventional coronary angiographies (control group, 46 patients). The fusion group included patients for whom a previous chest CT scan with contrast was available. For patients in this group, aorta and CABG were reconstructed in 3D from CT acquisitions and merged in real time with fluoroscopic images. The following parameters were compared: time needed to localize the CABG; procedure duration; air kerma (AK); dose area product (DAP); and volume of contrast media injected. Results are expressed as median. There were no significant differences between the 2 groups in patient demographics and procedure characteristics (access site, number of bypass to be found, and interventional cardiologist's experience). The time to localize CABG was significantly shorter in the fusion group (7.3 versus 12.4 minutes; P=0.002), as well as the procedure duration (20.6 versus 25.6 minutes; P=0.002), AK (610 versus 814 mGy; P=0.02), DAP (4390 versus 5922.5 cGy·cm(2); P=0.02), and volume of iodinated contrast media (85 versus 116 cc; P=0.002). CONCLUSIONS 3D image fusion improves the CABG detection in coronary angiography and reduces the time necessary to localize CABG, total procedure time duration, radiation exposure, and volume of contrast media.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noninvasive evaluation of coronary artery bypass grafts and native coronary arteries: is 16-slice multidetector CT useful?

PURPOSE To investigate the diagnostic accuracy and limitations of 16-slice multidetector computed tomography (MDCT) in the detection of significant ( > 50%) stenosis of coronary artery bypass grafts (CABG) and native coronary arteries. MATERIALS AND METHODS One hundred two patients with 236 grafts were investigated by 16-slice MDCT. Native coronary arteries were also investigated. The image q...

متن کامل

Myocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]

Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...

متن کامل

Non-invasive assessment of coronary artery bypass graft patency using 16-slice computed tomography angiography

BACKGROUND Invasive coronary angiography is the gold standard means of imaging bypass vessels and carries a small but potentially serious risk of local vascular complications, including myocardial infarction, stroke and death. We evaluated computed tomography as a non-invasive means of assessing graft patency. METHODS Fifty patients with previous coronary artery bypass surgery who were listed...

متن کامل

The factors that affect blood and blood products usage in coronary artery graft surgery

Background: Coronary artery bypass surgery is one of the surgeries in which high blood transfusions are needed. About 20% of all surgical operations require a blood transfusion. Packed cell administration increases perioperative morbidity and mortality. In the United States, from every 1000 people, one has undergone a coronary artery bypass graft surgery, and it is estimated that around 800,000...

متن کامل

Coronary artery bypass grafts: ECG-gated multi-detector row CT angiography--influence of image reconstruction interval on graft visibility.

PURPOSE To evaluate the influence of different reconstruction intervals of retrospectively electrocardiographically (ECG)-gated multi-detector row computed tomographic (CT) angiography on image quality of different segments of various types of coronary artery bypass grafts. MATERIALS AND METHODS Twenty consecutive patients with 62 grafts underwent retrospectively ECG-gated four-channel multi-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2016