Bioimpedance and echocardiography used interchangeably in volume comparison of dialysis patients.

نویسندگان

  • E Hur
  • G Yildiz
  • S Budak Kose
  • F Kokturk
  • O Musayev
  • O Gungor
  • K Magden
  • I Yildirim
  • S Duman
  • E Ok
چکیده

BACKGROUND Euvolemia is a major issue in chronic kidney disease. The present study compares cardiac condition and volume status in peritoneal dialysis (PD) and hemodialysis (HD) patients and points out importance of volume control. METHODS From a single-center center, 81 PD and 89 HD patients were enrolled. Echocardiography and body composition analysis using bioimpedance spectroscopy (BIS) technique were performed. Overhydration (OH) and extracellular water (ECW) in liters and OH/ECW % were used as volume indices. RESULTS Patients were younger (47.6±14. 5 and 53.1±11.8 years, p< 0.05), daily urine volume higher (1068±926 vs 290±444 ml, p <0.001) and dialysis vintage was shorter (30.1±18.6 vs 53.6±35.4 months, p<0.001), systolic blood pressure was lower (127.5±15.4 vs 140.3±18.9 mmHg, p<0.001) in PD than HD group respectively. Volume indices were (OH, OH/ECW %, ECW/height, ECW to Intracellular Water ratios (E/I) (p<0.05)) significantly higher in HD patients compared to PD patients. Over all 66 of 170 patients (39%) had OH/ECW % <5 and OH/ECW % ratio was positively correlated with Left atrium index (R(2):0.105, p<0.05). Interventricular septum diameter and Left ventricular mass index (1.41±0.24 and 159.6±48.2 vs. 1.27±0.17 cm and 115.8±37 g/m(2), p<0.001) were increased in HD than in PD group. After multivariate adjustment OH/ECW increased with: HD and diabetic patients. LVH increased with: HD group, OH/ECW (%) and SBP significantly. CONCLUSION Overhydration was more common among HD. Excess fluid may lead adverse effect in organ functions especially cardiac condition. This indicates that the current clinical and technical tools to achieve euvolemia are insufficient and that an additional tool, such as BIS, could be useful in the diagnosis of overhydration.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bioimpedance spectroscopy for the detection of hypervolemia in peritoneal dialysis patients.

A practical, inexpensive, and reliable method is needed for the assessment of volume status in peritoneal dialysis (PD) patients. In the present study, we investigated the efficiency of bioimpedance spectroscopy (BIS) for detection of hypervolemia. The study enrolled 79 prevalent PD patients (mean age: 47 +/- 14 years; PD duration: 30 +/- 17 months; 55% men; 19% with diabetes) from a single cen...

متن کامل

Comparison of electrical velocimetry and transoesophageal Doppler echocardiography for measuring stroke volume and cardiac output.

BACKGROUND Impedance cardiography (ICG) has been used extensively to estimate stroke volume (SV) and cardiac output (CO) from changes of thoracic electrical bioimpedance (TEB). However, studies comparing ICG with reference methods have questioned the reliability of this approach. Electrical velocimetry (EV) provides a new algorithm to calculate CO from variations in TEB. As the transoesophageal...

متن کامل

Bioimpedance for assessing volume status in children with nephrotic syndrome.

BACKGROUND/AIM The effectiveness of assessing volume load via bioimpedance in pediatric patients with nephrotic syndrome (NS) was investigated. MATERIALS AND METHODS Patients with NS (n = 34) were compared with healthy controls (n = 20). The inferior vena cava index and inferior vena cava collapsibility index (IVCCI) scores were determined for all subjects. Bioimpedance measurements were used...

متن کامل

Comparison of bioimpedance methods for estimating total body water and intracellular water changes during hemodialysis.

BACKGROUND The accurate assessment of body fluid volume is important in many clinical situations. Hannan et al. proposed a single-frequency bioimpedance equation (HE) to calculate extracellular water (ECW) and total body water (TBW). There are two equations based on the bioimpedance spectroscopy (BIS) method for the evaluation of body fluid volume: Xitron equations (XE) and body composition spe...

متن کامل

Can aortic elastic parameters be used for the diagnosis of volume overload in patients with end stage renal disease.

BACKGROUND We aimed here to investigate hydration status by echocardiography in end stage renal disease (ESRD) patients. METHODS 25 ESRD patients [15 males; mean age: 54.0±16.6 years; 13 hemodialysis; 12 peritoneal dialysis] were considered eligible for this study. We also examined 29 healthy volunteers as a control group (17 males; mean age: 46.5±12.8 years). Body composition analysis using ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Hippokratia

دوره 16 4  شماره 

صفحات  -

تاریخ انتشار 2012