Do we need to monitor cardiac output during major surgery?
نویسندگان
چکیده
1151 December 2012 T is strong evidence that optimizing stroke volume or cardiac output during major surgical procedures is associated with better outcomes.1–3 With this approach, interventions, consisting primarily of fluid administration, are given until there is no further increase in stroke volume, that is, when the FrankStarling relation reaches a plateau. In this issue of ANESTHESIOLOGY, Dr. Le Manach et al.4 evaluate a new technique to assess changes in cardiac output during fluid administration in the surgical patient. In this context, it is interesting to return to the first measurements of cardiac output during surgery more than 50 yr ago5; the method used, based on dyedilution techniques (fig. 1), revealed unsuspected changes, including a 20% decrease in cardiac output, during induction of anesthesia. So is monitoring cardiac output necessary to assess the response to fluids in this situation? It is widely appreciated that changes in arterial pressure do not reliably reflect changes in cardiac output, because the body employsmechanisms to preserve tissue perfusion pressure when stroke volume falls. However, predicting response to fluid administration could be facilitated by examining changes in pulse pressure during the respiratory cycle, because cyclic changes in intrathoracic pressure may influence ventricular filling when stroke volume is preload dependent.6 The operative period, when patients are anesthetized, paralyzed and managed with volume-predetermined ventilation, is ideally suited for monitoring this pulse pressure variation (PPV). The presence of significant arrhythmia, atrial fibrillation in particular, is the most obvious limitation to this approach during surgery. The major problem with using PPV to predict fluid responsiveness is the area of uncertainty surrounding middle-range values, as these values can indicate other scenarios than just fluid responsiveness, making a specific diagnosis difficult. A fluid challenge is, thus, still required in many cases. Dr. Le Manach et al.,4 in the study published in this issue of Anesthesiology, went one step further than simply monitoring PPV and evaluated the change in PPV (dPPV) during administration of 400 ml of colloids. This technique involved a real fluid challenge, because the response was uncertain, and indeed only half the patients responded with an increase in cardiac output. As expected, although there were some changes in arterial pressure, these did not reliably reflect the changes in cardiac output. The authors have already reported that evaluation of PPV could be useful in some patients, but one quarter of the patients remained in a “gray zone” with values between 9 and 13%.7 They now report that dPPV during the fluid challenge reflected better the changes in cardiac output, with a smaller gray zone. A decrease in PPV of 3% or more during the fluid challenge reflected an increase of more than 15% in cardiac output with a sensitivity of 90% and a specificity of 77%. Importantly, the gray zone, which was for a dPPV between 2.2 and 4.7%, concerned only one in seven patients (14%). Study of the arterial pressure tracing can, thus, serve not only to predict but also to assess the response during a fluid challenge.The analysis was well performed by these experts, and the strengths of the study include its large size, involving 400 patients from four centers. It is hoped that automatic measurements of PPV and dPPV will soon be obtained routinely, and integrated into current monitoring systems with a continuous display on the monitor. We will be able to set alarms for PPV and dPPV limits and be able to evaluate the likelihood of a response to fluid PPV and the actual cardiac output response (dPPV). The next step will then clearly Do We Need to Monitor Cardiac Output during Major Surgery?
منابع مشابه
Congenital Hypofibrinogenemia Detected during Preoperative Workup for Major Cardiac Surgery
Afibrinogenemia or hypofibrinogenemia is a quantitative defect in fibrinogen. It is a rare disease with estimated frequency of 1 in 1,000,000 population. Routine preoperative screening tests of coagulation disorders are insufficient to detect subtle disorders of fibrinogen. Herein, we report a child who was supposed to undergo open cardiac surgery for a large atrial septal defect. Preoperative ...
متن کاملA comparison of the non-invasive ultrasonic cardiac output monitor (USCOM) with the oesophageal Doppler monitor during major abdominal surgery.
BACKGROUND Perioperative interventions, targeted to increase global blood flow defined by explicit measured goals, reduce postoperative complications. Consequently, reliable non-invasive estimation of the cardiac output could have far-reaching benefit. METHODS This study compared a non-invasive Doppler device - the ultrasonic cardiac output monitor (USCOM) - with the oesophageal Doppler monit...
متن کاملThe Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery
Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods: In thi...
متن کاملShould we offer the surgeon a break?
To the Editor: Le Manach et al. present a study demonstrating the experimental applicability of changes in pulse pressure variation (dPPV) for the prediction of changes in cardiac output (dCO). The study is accompanied by a panegyric editorial answering the rhetorical question whether we need to monitor CO during surgery with a resounding NO! We now have dPPV!1,2 There is, however, a number of ...
متن کاملClinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit.
BACKGROUND The USCOM ultrasonic cardiac output monitor (USCOM Pty Ltd, Coffs Harbour, NSW, Australia) is a non-invasive device that determines cardiac output by continuous-wave Doppler ultrasound. The aim of this study was to evaluate the accuracy of the USCOM device compared with the thermodilution technique in intensive care patients who had just undergone cardiac surgery. METHODS We conduc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Anesthesiology
دوره 117 6 شماره
صفحات -
تاریخ انتشار 2012