System to measure the range of motion of the joints of the human hand .
نویسندگان
چکیده
Today, the manual goniometer is a common tool used in clinical practice to measure the range of motion (ROM) of joints in the hand. This device is not only tedious and highly timeconsuming to use, but its accuracy mainly depends on the experience of the examiner. The majority of electronic goniometers currently available on the market exhibit these same limitations. This document presents the physical design and attributes of a system known as the MULTIELGON, which can be used automatically to obtain multiple measurements of the angles of the hand's small finger joints simultaneously using a novel angle-to-voltage transducer. The reproducibility and repeatability of the transducer were evaluated; low dispersion and high homogeneity were demonstrated. Correlation and Bland-Altman analyses were used to compare the accuracy of the novel transducer (A) and traditional manual goniometer (B); the correlation coefficient was 0.9995. The Bland-Altman analysis determined the limits of agreement (1.4° to 1.7°) with a 95% confidence interval for any variation between the instruments (A and B), which gave readings differing by less than 3.1°. Differences were sufficiently small to propose that the manual goniometer can be replaced by the transducer; moreover A is best to evaluate the hand's small finger joints than B. The system is comprised of the device, the interface and the MULTIELGON GUI. The device consists of 14 angle-to-voltage transducers that can be attached to joints in the hand using a PVC clamp and an elastic glove. The MULTIELGON can be utilized to evaluate patients, as well as record and manage ROM data for surgical and rehabilitation decisions.
منابع مشابه
3D Hand Motion Evaluation Using HMM
Gesture and motion recognition are needed for a variety of applications. The use of human hand motions as a natural interface tool has motivated researchers to conduct research in the modeling, analysis and recognition of various hand movements. In particular, human-computer intelligent interaction has been a focus of research in vision-based gesture recognition. In this work, we introduce a 3-...
متن کاملThe Intelligent Modeling of Human Hand Motion Using Magnetic Based Techniques
With increasing use of robots instead of human in industrial, medicine and military applications etc.the importance of research on designing and building of robots is increasing. In this paper variousmethods of the human hand motion simulation has been investigated and we used one of most commonmethod named Data-gloves which extract data from hand and then we simulated hand motion duringseveral...
متن کاملتعامل بین درون دادهای بینایی و حسی– عمقی برای کنترل دینامیکی پوسچر در افراد سالم
Objectives: Poor dynamic balance may expose an individual to the risk of falling. The role of proprioception systems have been well addressed in the literature; however, majority of previous studies have been conducted in static conditions. The main objective of this study was to evaluate the dynamic postural control of healthy individuals during perturbation on their base of support in eyes op...
متن کاملGrasp analysis of a four-fingered robotic hand based on Matlab simmechanics
The structure of the human hand is a complex design comprising of various bones, joints, tendons, and muscles functioning together in order to produce the desired motion. It becomes a challenging task to develop a robotic hand replicating the capabilities of the human hand. In this paper, the analysis of the four-fingered robotic hand is carried out where the tendon wires and a spring return me...
متن کاملLong Term Effects of Volar-Dorsal Wrist/ Hand Immobilization Splint on Motor Components and Function of Stroke Patients
Objectives: This study was designed to determine the effects of Volar-Dorsal Wrist/Hand Immobilization Splint on upper extremity motor components and function of stroke patients. Methods: fourteen patients were participated in this study. The patients were selected based on the inclusion and exclusion criteria, and were given the splint after a primary evaluation. They were re-evaluated afte...
متن کاملگزارش یک مورد نادر آسیب بسته تاندونهای فلکسور عمقی
Introduction: The usual causes of flexor tendon injuries in hand are penetrating wounds. Closed injury and avulsion of flexor tendon are rare and mostly occur as avulsion of flexor digitorum profundus tendon of ring finger from its bony insertion at distal phalanx. Closed avulsion of flexor digitorum superficialis is even rarer. The rarest is simultaneous closed avulsion of both flexors in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Revista de investigacion clinica; organo del Hospital de Enfermedades de la Nutricion
دوره 66 Suppl 1 شماره
صفحات -
تاریخ انتشار 2014