Glenohumeral contact forces in reversed anatomy shoulder replacement.

نویسندگان

  • Milad Masjedi
  • Garth R Johnson
چکیده

A major requirement to design an implant is to develop our understanding of the applied internal forces during everyday activities. In the absence of any basic apparatus for measuring forces directly, it is essential to rely on modelling. The major aim of this study was therefore to understand the biomechanical function of subjects with the reversed anatomy Bayley-Walker prosthesis, using an inverse dynamic shoulder model. In this context, the muscle and joint forces of 12 Bayley-Walker subjects were compared to those of 12 normal subjects during 12 activities of daily living. Maximum glenohumeral contact forces for normal and Bayley-Walker subjects were found to be 77% (+/-15) and 137% (+/-21) body weight for lifting a 2kg shopping bag, and the least forces 29% (+/-4) and 67% (+/-8) body weight for reaching to opposite axilla, respectively. For normal subjects, middle deltoid, supraspinatus and infraspinatus were found to be the most active muscles across the subjects and tasks. On the other hand, for implanted subjects with a lack of rotator cuff muscles, the middle deltoid and coracobrachialis muscles were found to be the most active. The biomechanical model can therefore be used in order to gain knowledge about the pathology as well as possible post surgical rehab for subjects with reversed shoulder replacement.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An instrumented implant for in vivo measurement of contact forces and contact moments in the shoulder joint.

To improve implant design, fixation and preclinical testing, implant manufacturers depend on realistic data of loads acting on the shoulder joint. Furthermore, these data can help to optimize physiotherapeutic treatment and to advise patients in their everyday living conditions. Calculated shoulder joint loads vary extremely among different authors [Anglin C, Wyss UP, Pichora DR. Glenohumeral c...

متن کامل

Technique and Application for Quantifying Dynamic Shoulder Joint Kinematics and Glenohumeral Joint Contact Patterns

The shoulder (glenohumeral) joint has the greatest range of motion of all human joints; as a result, it is particularly vulnerable to dislocation and injury. The ability to accurately measure dynamic in-vivo joint kinematics in 6-Degrees-of-Freedom (6-DOF) (translations and rotations) and subsequently quantify articular cartilage contact patterns of that joint has been and remains a difficult b...

متن کامل

Reversed Shoulder Arthroplasty in a Patient with Fixed Anterior Glenohumeral Dislocation

An anterior glenohumeral dislocation is a serious condition which can lead to soft tissue damage and substantial defects of the humeral head and glenoid. Disturbance of shoulder joint congruency and soft tissue balancing can lead to poor function and severe impairment in these patients [1]. Little is known about the results of shoulder arthroplasty for the treatment of fixed glenohumeral disloc...

متن کامل

Polyethylene Wear in Anatomic and Reversed Shoulder Prostheses

INTRODUCTION: Polyethylene wear is a recurrent problem in joint arthroplasty. In addition to permanent deformation or complete destruction of the component, small debris particles are also associated to inflammation reaction of the surrounding bone, eventually leading to the failure of the bound between the implant and the host bone, and implant loosening. In anatomic total shoulder arthroplast...

متن کامل

Comparison of an EMG-based and a stress-based method to predict shoulder muscle forces.

The estimation of muscle forces in musculoskeletal shoulder models is still controversial. Two different methods are widely used to solve the indeterminacy of the system: electromyography (EMG)-based methods and stress-based methods. The goal of this work was to evaluate the influence of these two methods on the prediction of muscle forces, glenohumeral load and joint stability after total shou...

متن کامل