A two-center comparative study of plastic and lumen-apposing large diameter self-expandable metallic stents in endoscopic ultrasound-guided drainage of pancreatic fluid collections

نویسندگان

  • Tiing Leong Ang
  • Pradermchai Kongkam
  • Andrew Boon Eu Kwek
  • Piyachai Orkoonsawat
  • Rungsun Rerknimitr
  • Kwong Ming Fock
چکیده

BACKGROUND AND OBJECTIVES Endoscopic ultrasound-guided drainage of walled-off pancreatic fluid collections (PFCs) (pseudocyst [PC]; walled-off necrosis [WON]) utilizes double pigtail plastic stents (PS) and the newer large diameter fully covered self-expandable stents (FCSEMS) customized for PFC drainage. This study examined the impact of type of stent on clinical outcomes and costs. PATIENTS AND METHODS Retrospective two-center study. Outcome variables were technical and clinical success, need for repeat procedures, need for direct endoscopic necrosectomy (DEN), and procedure-related costs. RESULTS A total of 49 (PC: 31, WON: 18) patients were analyzed. Initially, PS was used in 37 and FCSEMS in 12. Repeat transmural drainage was required in 14 (PS: 13 [9 treated with PS, 4 treated with FCSEMS]; FCSEMS: 1 [treated with PS]) due to stent migration (PS: 3; FCSEMS: 1) or inadequate drainage (PS: 10). Technical success was 100%. Initial clinical success was 64.9% (25/38) for PS versus 91.7% (11/12) for FCSEMS (P = 0.074). With repeat transmural stenting, final clinical success was achieved in 94.6% and 100%, respectively (P = 0.411). Compared to FCSEMS, PS was associated with greater need for repeat drainage (34.2% vs. 6.3%, P = 0.032). The need for and frequency of DEN was similar between both groups, but PS required more frequent balloon dilatation. PS was significantly cheaper for noninfected PC. Costs were similar for infected PC and WON. CONCLUSION PS was associated with a higher need for a second drainage procedure to achieve clinical success. The use of FCSEMS did not increase procedural costs for infected PC and WON.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endoscopic ultrasound-guided placement of AXIOS stent for drainage of pancreatic fluid collections.

Pancreatic fluid collections (PFCs) have conventionally been treated with surgery, percutaneous drainage, or with the more recently established endoscopic ultrasound (EUS)-guided drainage modality. Currently, endoscopic plastic or metallic stents are used for PFC drainage. Plastic stents present issues with stent migration and premature occlusion requiring frequent stent exchanges or placement ...

متن کامل

Comparative evaluation of two porcine ex vivo models for training in endoscopic ultrasound-guided drainage of pancreatic fluid collections

Ultrasound-guided drainage is the first-line modality for drainage of symptomatic of pancreatic fluid collections. In the context of pancreatic cancer, use of multiple double-pigtail plastic stents suffice, with high treatment efficacy. This approach provides similar success rates with low complications and better quality of life compared with surgery. Lumen apposing metallic stents (LAMSs) per...

متن کامل

Endoscopic ultrasound-guided placement of plastic pigtail stents for the drainage of refractory malignant ascites

Endoscopic ultrasound (EUS)-guided drainage is now the treatment of choice in cases of pancreatic pseudocysts and walled-off necrosis, especially in the absence of luminal bulging and in patients with portal hypertension. Malignant refractory ascites usually heralds a poor prognosis and substantially impairs the quality of life of patients because of the symptoms experienced and the need for re...

متن کامل

Endoscopic treatment of large pancreatic fluid collections (PFC) using self-expanding metallic stents (SEMS) – a two-center experience

UNLABELLED Background/study aim: During the last several years, endoscopic ultrasound (EUS)-guided pancreatic fluid collections' (PFC) drainage has evolved into the preferred drainage technique. Recently, self-expanding metallic stents (SEMS) have been used as an alternative to double pigtail stents, with the advantage of providing a larger diameter fistula, thereby decreasing the risk of early...

متن کامل

Safety and efficacy of endoscopic ultrasound-guided drainage of pancreatic fluid collections with lumen-apposing covered self-expanding metal stents.

BACKGROUND & AIMS Plastic stents, placed via endoscopy to drain pancreatic fluid collections (PFCs), require repeat access. Covered metal stents are larger in diameter and can be inserted in a single step, but can migrate. We evaluated the safety and efficacy of a lumen-apposing, covered, self-expanding metal stent (LACSEMS) for PFC drainage. METHODS We performed a prospective study of the ou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2016