Shape Memory Alloy Expandable Pedicle Screw to Enhance Fixation in Osteoporotic Bone: Primary Design and Finite Element Simulation
نویسندگان
چکیده
The properties of shape memory alloys, specifically the equiatomic intermetallic NiTi, are unique and significant in that they offer simple and effective solutions for some of the biomechanical issues encountered in orthopedics. Pedicle screws, used as an anchoring point for the implantation of spinal instrumentations in the spinal fracture and deformity treatments, entail the major drawback of loosening and backing out in osteoporotic bone. The strength of the screw contact with the surrounding bone diminishes as the bone degrades due to osteoporosis. The SMArt pedicle screw design is developed to address the existing issue in degraded bone. It is based on the interaction of bi-stable shape memory-superelastic elements. The bi-stable assembly acts antagonistically and consists of an external superelastic tube that expands the design protrusions when body temperature is attained; also an internal shape memory wire, inserted into the tube, retracts the assembly while locally heated to above the body temperature. This innovative bi-stable solution augments the pullout resistance while still allowing for screw removal. The antagonistic wire-tube assembly was evaluated and parametrically analyzed as for the interaction of the superelastic tube and shape memory wire using a finite element model developed in COMSOL Multiphysics R . The outcomes of the simulation suggest that shape memory NiTi inserts on the SMArt pedicle screw can achieve the desired antagonistic functionality of expansion and retraction. Consequently, a parametric analysis was conducted over the effect of different sizes of wires and tubes. The dimensions for the first sample of this innovative pedicle screw were determined based on the results of this analysis. [DOI: 10.1115/1.4007179]
منابع مشابه
Balancing Rigidity and Safety of Pedicle Screw Fixation via a Novel Expansion Mechanism in a Severely Osteoporotic Model
Many successful attempts to increase pullout strength of pedicle screws in osteoporotic bone have been accompanied with an increased risk of catastrophic damage to the patient. To avoid this, a single-armed expansive pedicle screw was designed to increase fixation strength while controlling postfailure damage away from the nerves surrounding the pedicle. The screw was then subsequently tested i...
متن کاملSurgical Strategies to Improve Fixation in the Osteoporotic Spine: The Effects of Tapping, Cement Augmentation, and Screw Trajectory
Study Design Biomechanical study of pedicle screw fixation in osteoporotic bone. Objective To investigate whether it is better to tap or not tap osteoporotic bone prior to placing a cement-augmented pedicle screw. Methods Initially, we evaluated load to failure of screws placed in cancellous bone blocks with or without prior tapping as well as after varying the depths of tapping prior to screw ...
متن کاملComparison of the Pullout Strength of Different Pedicle Screw Designs and Augmentation Techniques in an Osteoporotic Bone Model
Study Design Mechanical study. Purpose To compare the pullout strength of different screw designs and augmentation techniques in an osteoporotic bone model. Overview of Literature Adequate bone screw pullout strength is a common problem among osteoporotic patients. Various screw designs and augmentation techniques have been developed to improve the biomechanical characteristics of the bone-...
متن کاملPullout performance comparison of pedicle screws based on cement application and design parameters.
Pedicle screws are the main fixation devices for certain surgeries. Pedicle screw loosening is a common problem especially for osteoporotic incidents. Cannulated screws with cement augmentation are widely used for that kind of cases. Dual lead dual cored pedicle screw has already given promising pullout values without augmentation. This study concentrates on the usage of dual lead dual core wit...
متن کاملPossible usage of cannulated pedicle screws without cement augmentation
BACKGROUND: The use of pedicle screws is becoming increasingly popular for spinal surgery practice as the technology advances. Screw pullout due to bone quality and loading conditions is one of the most common problems observed after pedicle screw fixation. Several solutions were studied to prevent screw pullout. These can be investigated under three main categories: screw design, expandable sc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012