Amperometric biosensor based on glucose dehydrogenase and plasma-polymerized thin films.
نویسندگان
چکیده
A novel design is described for an amperometric biosensor based on NAD(P)-dependent glucose dehydrogenase (GDH) combined with a plasma-polymerized thin film (PPF). The GDH is sandwiched between several nanometer thick acetonitrile PPFs on a sputtered gold electrode (PPF/GDH/PPF/Au). The lower PPF layer plays the role as an interface between enzyme and electrode because it is extremely thin, adheres well to the substrate (electrode), has a flat surface and a highly-crosslinked network structure, and is hydrophilic in nature. The upper PPF layer (overcoating) was directly deposited on immobilized GDH. The optimized amperometric biosensor characteristics covered 2.5-26 mM glucose concentration at +0.6 V of applied potential; the least-squares slope was 320 nA mM(-1) cm(-2) and the correlation coefficient was 0.990. Unlike conventional wet-chemical processes that are incompatible with mass production techniques, this dry-chemistry procedure has great potential for enabling high-throughput production of bioelectronic devices.
منابع مشابه
Amperometric glucose biosensor based on mediated electron transfer between immobilized glucose oxidase and plasma-polymerized thin film of dimethylaminomethylferrocene on sputtered gold electrode.
We propose an electron transfer-mediated amperometric enzyme biosensor based on plasma-polymerized thin film of dimethylaminomethylferrocene (DMAMF) on a sputtered gold electrode. The DMAMF plasma-polymerized film is deposited directly onto the surface of the electrode under dry conditions. The resulting thin film not only has redox sites but also is extremely thin (approximately 20 nm), adhere...
متن کاملAn Amperometric Biosensor for Glucose Determination Prepared from Glucose Oxidase Immobilized in Polyaniline-Polyvinylsulfonate Film
In this study, a novel amperometric glucose biosensor with immobilization of glucose oxidase on electrochemically polymerized polyaniline-polyvinylsulphonate (Pani-Pvs) films has been accomplished via the entrapment technique. Electropolymerization of aniline on the Pt surface of the Pt electrode was carried out at constant potential (0.75 V, vs. Ag/AgCl) using an electrochemical cell containin...
متن کاملStructural And Optical Properties Of Plasma Polymerized Pyromucic Aldehyde Thin Films
Plasma polymerized pyromucic aldehyde (PPPA) thin films have been deposited on to glass substrates by glow discharge technique. Scanning electron microscopy (SEM) graphs reveal that the surface morphology of PPPA thin films is uniform and flawless. FTIR analysis reveals that the chemical composition of PPPA films is different from that of the pyromucic aldehyde (PA). From the UV-vis spectra dir...
متن کاملLayer-by-Layer Self-Assembling Gold Nanorods and Glucose Oxidase onto Carbon Nanotubes Functionalized Sol-Gel Matrix for an Amperometric Glucose Biosensor
A novel amperometric glucose biosensor was fabricated by layer-by-layer self-assembly of gold nanorods (AuNRs) and glucose oxidase (GOD) onto single-walled carbon nanotubes (SWCNTs)-functionalized three-dimensional sol-gel matrix. A thiolated aqueous silica sol containing SWCNTs was first assembled on the surface of a cleaned Au electrode, and then the alternate self-assembly of AuNRs and GOD w...
متن کاملAn amperometric glucose biosensor based on glucose oxidase immobilized in electropolymerized poly(o-aminophenol) and carbon nanotubes composite film on a gold electrode.
An amperometric glucose biosensor is developed that is based on immobilization of glucose oxidase (GOD) in a composite film of poly(o-aminophenol) (POAP) and carbon nanotubes (CNT), which are electrochemically co-polymerized at a gold (Au) electrode. Because of the high surface per volume ratio and excellent electrical conductivity of CNT, the biosensor based on an Au/POAP/CNT/GOD electrode has...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 24 4 شماره
صفحات -
تاریخ انتشار 2008