Quantitative image contrast enhancement in time-gated transillumination of scattering media.
نویسندگان
چکیده
Experimental work in turbid media has shown that trans-illumination images can be significantly improved by limiting light collection to a subset of photons which are minimally distorted by scattering. The literature details numerous schemes (commonly termed ballistic imaging), most often based on time-gating and/or spatially filtering the detected light. However, due to the complex nature of the detected signal, analysis of this optical filtering process has been heretofore limited to qualitative comparisons of image results. In this article we present the implementation of a complete system model for the simulation of light propagation, including both the scattering medium and all stages of the optical train. Validation data from ballistic imaging (BI) measurements of monodisperse scatterers with diameter, d = 0.7 µm, at optical depths 5, 10, and 14, are compared with model results, showing excellent agreement. In addition, the validated model is subsequently applied to a modified time-gated optical system to probe the comparative performance of the BI system used in validation and the modified BI system. This instrument comparison examines scatterers with diameters of 0.7 and 15 µm at optical depths 10 and 14, and highlights the benefits of each system design for these specific scattering conditions. These results show that the modified optics configuration is more suitable for particles which are much larger than the incident wavelength, d >> λ, while the configuration employed in the validation system provides a better contrast for particle diameters on the order of the wavelength, d ~λ, where the scattering process exhibits a more homogeneous phase function. The insights and predictions made available by the full numerical model are important for the design of optimized imaging systems suited to specific turbid media, and make possible the quantitative understanding of both the effects of light propagation in the measurement and the performance of the complete imaging system.
منابع مشابه
Resolution Bounds and Reconstruction Techniques for Time-resolved Transillumination Imaging
Recent technological advances now enable time-gated acquisition of photons at very fast rates. This allows one to separate scattered and unscattered photons by temporal gating, a process termed time-resolved transillumination (TRT) imaging. TRT imaging opens the door to a new type of scanning through turbid (scattering) media such as soft tissue and fog/smoke, and many potential applications in...
متن کاملFemtosecond transillumination optical coherence tomography.
We describe a new technique, femtosecond transillumination optical coherence tomography, for time-gated imaging of objects embedded in scattering media. Time gating is performed with a fiber-optic interferometer with femtosecond pulses and coherent heterodyne detection to achieve a 130-dB dynamic range. A confocal imaging arrangement provides additional spatial discrimination against multiply s...
متن کاملA Quantitative Investigation on the Effect of Edge Enhancement for Improving Visual Acuity at Different Levels of Contrast
Background: The major limitation in human vision is refractive error. Auxiliary equipment and methods for these people are not always available. In addition, limited range of accommodation in adult people when switching from a far point to a near point is not simply possible. In this paper, we are looking for solutions to use the facilities of digital image processing and displaying to improve ...
متن کاملAssessment of Contrast Media Volume Injected and Image Contrast in Abdominal Pelvic CT Scan and Related Factors in Referral Hospitals in Mazandaran, Iran
Background and purpose: Computed tomography scan (CT) is highly capable of diagnosing abdominal and pelvic lesions. Injection of contrast media at appropriate concentration and volume provides the least side effects and the highest image quality. This study aimed at investigating the volume of contrast medium injected and the level of image contrast compared to the standard model, in the imagi...
متن کاملDeveloping a PC-based portal image contrast enhancement program
ABSTRACTBackground: Delivering the radiation dose to the target volume and minimizing the dose to normal tissues are the main objectives in radiotherapy. The aim of our study is to enhance the contrast of the portal image to increase the accuracy of delineation of the organs in the irradiation field. Methods: The software was written based on local enhancement of the pixel values in image ma...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optics express
دوره 19 3 شماره
صفحات -
تاریخ انتشار 2011