Prosthetics socket that incorporates an air splint system focusing on dynamic interface pressure

نویسندگان

  • Nasrul Anuar Abd Razak
  • Noor Azuan Abu Osman
  • Hossein Gholizadeh
  • Sadeeq Ali
چکیده

BACKGROUND The interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. This paper presents the design and performance of a new prosthetic socket that uses an air splint system. METHODS The air splint prosthetic socket system was implemented by combining the air splint with a pressure sensor that the transhumeral user controls through the use of a microcontroller. The modular construction of the system developed allows the FSR pressure sensors that are placed inside the air splint socket to determine the required size and fitting for the socket used. Fifteen transhumeral amputees participated in the study. RESULTS The subject's dynamic pressure on the socket that's applied while wearing the air splint systems was recorded using F-socket transducers and microcontroller analysis. The values collected by the F-socket sensor for the air splint prosthetic socket system were determined accordingly by comparing the dynamic pressure applied using statically socket. The pressure volume of the air splint fluctuated and was recorded at an average of 38 kPa (2.5) to 41 kPa (1.3) over three hours. CONCLUSION The air splint socket might reduce the pressure within the interface of residual limb. This is particularly important during the daily life activities and may reduce the pain and discomfort at the residual limb in comparison to the static socket. The potential development of an auto-adjusted socket that uses an air splint system as the prosthetic socket will be of interest to researchers involved in rehabilitation engineering, prosthetics and orthotics.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration problems encountered while monitoring stump/socket interface pressures with force sensing resistors: techniques adopted to minimise inaccuracies.

Force sensing resistors (FSR) have been used to measure dynamic pressures at the interface between appliance and patient. Inaccuracies using FSRs have been reported. This paper summarises both the calibration problems encountered and the techniques adopted to minimise inaccuracies. It is considered that, by calibrating the transducers attached to the socket, and by adopting a strict test protoc...

متن کامل

A comparison between the dimensions of positive transtibial residual limb molds prepared by air pressure casting and weight-bearing casting methods

Background: Creating a socket with proper fit is an important factor to ensure the comfort and control of prosthetic devices. Several techniques are commonly used to cast transtibial stumps but their effect on stump shape deformation is not well understood. This study compares the dimensions, circumferences and volumes of the positive casts and also the socket comfort between two casting method...

متن کامل

A new method for the measurement of normal pressure between amputation residual limb and socket.

Present address : Orthopaedic Workshop "Anna Kliniek", Mezenstraat 2, 2333 Leiden, the Netherlands. b Present address : Prins Frisolaan 20, 7242 GZ Lochem, the Netherlands. « Laoummimsveuuovs, unxmrsn~ pa,/s xx INTRODUCTION The measurement of normal pressures at an interface is a universal problem in prosthetics (1, 2, 3). One difficulty is that the existing pressure pattern is disturbed by the...

متن کامل

Relationship between socket pressure and EMG of two muscles in trans-femoral stumps during gait.

The biomechanical interaction between the leg stump and the prosthetic socket is critical in achieving close-to-normal ambulation. Although many investigations have been performed to understand the biomechanics of trans-tibial sockets, few studies have measured the socket interface pressure for transfemoral amputees. Furthermore, no report has examined how the residual muscle activities in the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2014