Implementation of an improved dose‐per‐MU model for double‐scattered proton beams to address interbeamline modulation width variability

نویسندگان

  • Liyong Lin
  • JiaJien Shen
  • Christopher G. Ainsley
  • Timothy D. Solberg
  • James E. McDonough
چکیده

Because treatment planning systems (TPSs) generally do not provide monitor units (MUs) for double-scattered proton plans, models to predict MUs as a function of the range and the nominal modulation width requested of the beam delivery system, such as the one developed by the MGH group, have been proposed. For a given nominal modulation width, however, the measured modulation width depends on the accuracy of the vendor's calibration process and may differ from this nominal value, and also from one beamline to the next. Although such a difference can be replicated in our TPS, the output dependence on range and modulation width for each beam option or suboption has to be modeled separately for each beamline in order to achieve maximal 3% inaccuracy. As a consequence, the MGH output model may not be directly transferable. This work, therefore, serves to extend the model to more general clinic situations. In this paper, a parameterized linear-quadratic transformation is introduced to convert the nominal modulation width to the measured modulation width for each beam option or suboption on a per-beamline basis. Fit parameters are derived for each beamline from measurements of 60 reference beams spanning the minimum and maximum ranges, and modulation widths from 2 cm to full range per option or suboption. Using the modeled modulation width, we extract the MGH parameters for the output dependence on range and modulation width. Our method has been tested with 1784 patient-specific fields delivered across three different beamlines at our facility. For these fields, all measured outputs fall within 3%, and 64.4% fall within 1%, of our model. Using a parameterized linear-quadratic modulation width, MU calculation models can be established on a per-beamline basis for each double scattering beam option or suboption.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of Various Beam Parameters on Lateral Scattering in Proton and Carbon-ion Therapy

Background: In radiation therapy with ion beams, lateral distributions of absorbed dose in the tissue are important. Heavy ion therapy, such as carbon-ion therapy, is a novel technique of high-precision external radiotherapy which has advantages over proton therapy in terms of dose locality and biological effectiveness.Methods: In this study, we used Monte Carlo method-based Geant4 toolkit to s...

متن کامل

A new model for Spread Out Bragg Peak in proton therapy of uveal melanoma

In this research, in order to improve our calculations in treatment planning for proton radiotherapy of ocular melanoma, we improved our human eye phantom planning system in GEANT4 toolkit. Different analytical models have investigated the creating of Spread Out Bragg Peak (SOBP) in the tumor area. Bortfeld’s model is one of the most important analytical methods. Using convolution method, a new...

متن کامل

Dosimetry limitations and pre-treatment dose profile correction for sliding window IMRT

Background: This work investigated the dosimetry limitations of the random and systematic uncertainties of sliding window (SW) intensity modulated radiation therapy (IMRT). Materials and Methods: A Varian 21EX linear accelerator, Pinnacle3 treatment planning system and radiographic film dosimetry was used. The limitations of the SW were studied using beam modulation ranging from 2 to 10...

متن کامل

Energy optimization procedure for treatment planning with laser-accelerated protons.

A simple analytical model is found that predicts the exact proton spectrum needed to obtain a spread-out-Bragg peak (SOBP) distribution for laser-accelerated proton beams. The theory is based on the solution to the Boltzmann kinetic equation for the proton distribution function. The resulting analytical expression allows one to calculate the SOBP proton energy spectra for the different beamlet ...

متن کامل

Time‐resolved diode dosimetry calibration through Monte Carlo modeling for in vivo passive scattered proton therapy range verification

PURPOSE Our group previously introduced an in vivo proton range verification methodology in which a silicon diode array system is used to correlate the dose rate profile per range modulation wheel cycle of the detector signal to the water-equivalent path length (WEPL) for passively scattered proton beam delivery. The implementation of this system requires a set of calibration data to establish ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014