A LIGHT SCATTERING INVESTIGATION OF DROPLET GROWTH IN NOZZLE CONDENSATION by

نویسندگان

  • Richard Roberts
  • Kenneth C. Russell
چکیده

An experimental and theoretical study has been made of the condensation of water vapor (with air carrier) in a supersonic nozzle in order to investigate the possible existence of condensate droplets which are substantially larger than predicted by the standard application of classical condensation theory. Droplet size was measured using light scattering techniques, which when combined with the total mass concentration of condensate, provided limits on the maximum and average droplet size. It was found that approximately one part in 103 of the droplet concentration reached a size a factor of 10 greater than predicted by the classical theory (radius in range 400 1000 A for water mass fractions in range .005 < wo < .015). The maximum droplet size, furthermore, was not seen to decrease proportionately as the nucleation zone was approached, indicating that the larger droplets are formed during the early stages of condensation. Inconclusive evidence suggests that this occurs following the completion of nucleation but before the vapor supply is exhausted. A calculation procedure which allowed the separation of the nuclei into a distribution of sizes, arising from a varying stability criterion and radius dependent growth rate, resulted in the establishment of a qualitatively correct distribution shape but no theoretical substantiation of an aging or coarsening mechanism. A separate application of Brownian coagulation theory to surface-averaged condensation theory resulted in the prediction that the average droplet size increased by a factor of between 2.5 and 4. No conclusion could be drawn concerning the actual existence of this size increase due to the level of uncertainty in the determination of average droplet size. Thesis Supervisor: Philip G. Hill Title: Associate Professor of Mechanical Engineering Head, Dept. of Mechanical Engineering Queen's University, Kingston, Ontario

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Theoretical Mass Transfer Approach for Prediction of Droplets Growth Inside Supersonic Laval Nozzle

Proper estimation of droplet growth rate plays a crucial role on appropriate prediction of supersonic separators performance for separation of fine droplets from a gas stream. Up to now, all available researches employ empirical or semi-empirical correlations to define the relationship between droplet growth rate (dr/dt) and other operating variables such as temperatures (T and TL), Pressure (P...

متن کامل

Numerical Simulation of Non-Equilibrium Two-Phase Wet Steam Flow through an Asymmetric Nozzle

The present study reported of the numerical investigation of a high-speed wet steam flow through an asymmetric nozzle. The spontaneous non-equilibrium homogeneous condensation of wet steam was numerically modeled based on the classical nucleation theory and droplet growth rate equation combined with the field conservations within the computational fluid dynamics (CFD) code of ANSYS Fluent 13.0....

متن کامل

Entrapment–D-(+)-Glucose Water Nanodroplet: Synthesis and Dynamic Light Scattering

In the present research, the D-(+)-Glucose–confined water nanodroplets with mean size in the range of 6-11 nm were synthesized at D-(+)-Glucose different concentrations by AOT reverse micelles (RMs) method as a function of mass fraction of droplet (MFD) at the constant water-to-surfactant molar ratio ( W=40). The dynamic light scattering of the nano-sized water droplets containing the D-(+)-Glu...

متن کامل

Measurements of Diesel Spray Droplet Size with Ultra-Small Angle X-Ray Scattering

The strong scattering of visible light by spray droplets has severely impeded the ability of optical diagnostics to probe dense sprays. X-rays interact more weakly with spray droplets than visible light; as such, multiple scattering effects are rarely important in the x-ray regime. As such, x-ray radiography (which relies on absorption) and x-ray phase-contrast imaging (which relies on subtle r...

متن کامل

Measurements of Submicron Fog Particles Generated in a Nozzle

-Measurements were made of the size and relative number of particles condensed in a "large" supersonic nozzle. Stagnation temperature was held at 528°R and stagnation pressure was varied from ~ 1/3 to ~ 2/3 atm with the water as the condensing vapor. The mass fraction of water vapor was varied from ~8 x 10 -3 to ~30 × 10 -3. The size of particles was determined by measurement of light scattered...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006