BACKGROUND AND PURPOSE Diffuse axonal injury (DAI) is a common type of primary neuronal injury in patients with severe traumatic brain injury (TBI), and is frequently accompanied by tissue tear hemorrhage. T2-weighted gradient-recalled echo (GRE) sequences are more sensitive than T2-weighted spin-echo images for detection of hemorrhage. The purpose of this study is to compare turbo Proton Echo Planar Spectroscopic Imaging (t-PEPSI), an extremely fast sequence, with GRE sequence in the detection of DAI. METHODS Twenty-one patients (mean age 26.8 years) with severe TBI occurred at least 3 months earlier, underwent a brain MR Imaging study on a 1.5-T scanner. A qualitative evaluation of the t-PEPSI sequences was performed by identifying the optimal echo time and in-plane resolution. The number and size of DAI lesions, as well as the signal intensity contrast ratio (SI CR), were computed for each set of GRE and t-PEPSI images, and divided according to their anatomic location as lobar and/or deep brain. RESULTS There was no significant difference between GRE and t-PEPSI sequences in the detection of the total number of DAI lesions (291 vs. 230, respectively). GRE sequence delineated a higher number of DAI in the temporal lobe compared to the t-PEPSI sequence (74 vs. 37, P < .004), while no differences were found for the other regions. The SI CR was significantly lower with the t-PEPSI than the GRE sequence (P < .00001). CONCLUSION Owing to its very short scan time and high sensitivity to the hemorrhage foci, the t-PEPSI sequence may be used as an alternative to the GRE to assess brain DAI in severe TBI patients, especially if uncooperative and medically unstable.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

Teaching NeuroImages: Usefulness of susceptibility-weighted sequences after traumatic brain injury.

Three weeks after severe traumatic brain injury (pedestrian hit by a car) and correction of initial intracranial hypertension, a brain MRI is performed in a 22-yearold woman, who remains in a comatose state (Glasgow Coma Scale at 4, with withdrawal to painful stimuli; abolition of photomotor reflex; persistence of corneal and cough reflexes). Fluid-attenuated inversion recovery and T2*-weighted...

متن کامل

Traumatic brain injury: diffusion-weighted MR imaging findings.

BACKGROUND AND PURPOSE Diffuse axonal injury (DAI) accounts for a significant portion of primary intra-axial lesions in cases of traumatic brain injury. The goal of this study was to use diffusion-weighted MR imaging to characterize DAI in the setting of acute and subacute traumatic brain injury. METHODS Nine patients ranging in age from 26 to 78 years were examined with conventional MR imagi...

متن کامل

Diffuse axonal injury associated with chronic traumatic brain injury: evidence from T2*-weighted gradient-echo imaging at 3 T.

BACKGROUND AND PURPOSE Diffuse axonal injury is frequently accompanied by tissue tear hemorrhages. We examined whether high field strength T2*-weighted gradient-echo imaging performed during the chronic stage of traumatic brain injury may have advantages in the evaluation of diffuse axonal injury as compared with T1- and T2-weighted MR imaging. METHODS Prospective MR imaging of 66 patients (a...

متن کامل

Detection of intracranial hemorrhage: comparison between gradient-echo images and b0 images obtained from diffusion-weighted echo-planar sequences on 3.0T MRI.

In this study, we compared the effectiveness of b0 echo-planar MR images (EPI) imaging with gradient recalled echo (GRE) in detecting acute hemorrhage. Brain images in 69 patients who suffered from acute infarction were reviewed. Nine of them had suffered from acute hemorrhage. Comparing b0EPI and GRE images side-by-side, we found no significant different effectiveness in detecting hemorrhage (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 26 5  شماره 

صفحات  -

تاریخ انتشار 2005