Magnetic levitation in the analysis of foods and water.
نویسندگان
چکیده
This paper describes a method and a sensor that use magnetic levitation (MagLev) to characterize samples of food and water on the basis of measurements of density. The sensor comprises two permanent NdFeB magnets positioned on top of each other in a configuration with like poles facing and a container filled with a solution of paramagnetic ions. Measurements of density are obtained by suspending a diamagnetic object in the container filled with the paramagnetic fluid, placing the container between the magnets, and measuring the vertical position of the suspended object. MagLev was used to estimate the salinity of water, to compare a variety of vegetable oils on the basis of the ratio of polyunsaturated fat to monounsaturated fat, to compare the contents of fat in milk, cheese, and peanut butter, and to determine the density of grains.
منابع مشابه
Tuned Parameters of PID for Optimization of Losses in Magnetic Levitation System
In this paper a new method is proposed for determining PID controller parameters in order to decrease losses in levitation system of magnetic trains. It is assumed that this system is a hybrid system and it consists of electric and permanent magnet. For optimization of losses initially AC losses of magnetic levitation system are calculated. Linear model of levitation system as well as modeling ...
متن کاملUse of Magnetic Resonance Imaging in Food Quality Control: A Review
Modern challenges of food science require a new understanding of the determinants of food quality and safety. Application of advanced imaging modalities such as magnetic resonance imaging (MRI) has seen impressive successes and fast growth over the past decade. Since MRI does not have any harmful ionizing radiation, it can be considered as a magnificent tool for the quality control of food prod...
متن کاملOffline Auto-Tuning of a PID Controller Using Extended Classifier System (XCS) Algorithm
Proportional + Integral + Derivative (PID) controllers are widely used in engineering applications such that more than half of the industrial controllers are PID controllers. There are many methods for tuning the PID parameters in the literature. In this paper an intelligent technique based on eXtended Classifier System (XCS) is presented to tune the PID controller parameters. The PID controlle...
متن کاملStray-field nuclear magnetic resonance imaging in microgravity conditions
Magnetic levitation has been proposed as an alternative approach to simulate on Earth microgravity conditions encountered in space, allowing the investigation of weightlessness on materials and biological systems. In general, very strong magnetic fields, 15 T or higher, are required to achieve levitation for a majority of diamagnetic substances. Here, we show that it is possible to achieve levi...
متن کاملDiamagnetically stabilized magnet levitation
Stable levitation of one magnet by another with no energy input is usually prohibited by Earnshaw’s Theorem. However, the introduction of diamagnetic material at special locations can stabilize such levitation. A magnet can even be stably suspended between (diamagnetic) fingertips. A very simple, surprisingly stable room temperature magnet levitation device is described that works without super...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of agricultural and food chemistry
دوره 58 11 شماره
صفحات -
تاریخ انتشار 2010