A Fast Chromatographic Method for Determination of Daidzein and Genistein in Spiked Water River Samples Using Multivariate Curve Resolution
نویسندگان
چکیده
This work reports the development of a fast chromatographic methodology for quantitation of two phytoestrogens: daidzein (DAI), and genistein (GEN), in river water samples. The proposed method is based on high performance liquid chromatography-diode array detection (HPLC-DAD) data, and multivariate curve resolution-alternative least square (MCR-ALS) second-order calibration. Initially, the method was evaluated analyzing a synthetic validation set; prepared based on a Taguchi design. Subsequently, the method was applied to predict the concentration of the phytoestrogens in spiked river water samples, previously pre-processed by solid phase extraction (SPE). By implementation of the present chromatographic methodology, a 50% reduction in operation time was achieved (from 7.00 to 3.25 min) when compared with previous work in the literature. Precision was achieved even in the presence of non-modeled constituents and strong background. Thus, the proposed method is a rapid and robust alternative for the quantitation of studied phytoestrogens.
منابع مشابه
Comparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma
An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...
متن کاملComparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma
An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...
متن کاملSpectrophotometric Multicomponent Analysis of Ternary and Quaternary Drug Mixtures in Human Urine Samples by Analyzing First-order Data
A new method was developed for the spectral resolution by further determination of three- and four-component mixtures of drugs in urine samples through the complementary application of multivariate curve resolution-alternating least squares with correlation constraint. In the current study, a simple method was proposed to construct a calibration set for the mixture of drugs in the p...
متن کاملSimultaneous Determination of Ibuprofen and Caffeine in Urine Samples by Combining MCR-ALS and Excitation-emission Data
Second order advantage of excitation-emission fluorescence matrix was applied for the simultaneous determination of ibuprofen and caffeine. The proposed method is based on the measurement of the native fluorescence and recording emission spectra of ibuprofen and caffeine in different excitation wavelengths. The mixture of these compounds was resolved by multivariate curve resolution coupled wit...
متن کاملCoupling Second-Order Excitation-Emission Spectrofluorimetric Data with Standard Addition method to Quantify Carvedilol in Real Samples
Prediction using pure standards is expected to be biased whenever the slope of the calibration is affected by the presence of sample matrix. Moreover, in the presence of unknown spectral interferents, first-order algorithms like partial least squares cannot be used. In this study, a method for determination of carvedilol (CAR) in tablet and urine samples is proposed by excitation-emission fluor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -