MR imaging of the cavernous sinus: value of spin echo and gradient recalled echo images.

نویسندگان

  • D L Daniels
  • L F Czervionke
  • J F Bonneville
  • F Cattin
  • L P Mark
  • P Pech
  • L E Hendrix
  • D F Smith
  • V M Haughton
  • A L Williams
چکیده

A detailed evaluation of the MR appearance of the pituitary gland-cavernous sinus junction has not been described. In a series of coronal T1-weighted spin echo images without and with IV gadolinium, we noted the variable size and signal intensity of cavernous venous spaces adjacent to the pituitary gland and the inconsistent visualization of the dural membrane just lateral to the gland. Correlation of coronal T1-weighted spin echo and gradient recalled echo images (the latter with high-signal-intensity vascular structures) proved to be an effective means of identifying cavernous venous spaces, connective tissue and cranial nerves, and the lateral margins of the pituitary gland, and of differentiating tumor tissue from cavernous venous spaces. Further work is needed to develop criteria to distinguish cavernous sinus compression from actual tumor invasion.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional FISP imaging in the evaluation of carotid cavernous fistula: comparison with contrast-enhanced CT and spin-echo MR.

PURPOSE The purpose of this study was to assess the value of three-dimensional fast imaging with steady-state precession (FISP) MR sequences relative to contrast-enhanced CT and spin-echo MR imaging in the diagnosis of carotid cavernous fistula (CCF). METHODS Seventeen patients with 19 angiographically proved CCFs had contrast-enhanced CT, spin-echo MR imaging, and 3-D FISP imaging. Three obs...

متن کامل

Dural sinus occlusion: evaluation with phase-sensitive gradient-echo MR imaging.

The purpose of this study was to evaluate the usefulness of limited-flip-angle, phase-sensitive velocity imaging with gradient-recalled-echo (VIGRE) MR when combined with spin-echo MR in the diagnosis of dural sinus thrombosis. The VIGRE sequence consists of a rapid single-slice acquisition, 50/15/2 (TR/TE/excitations), and 30 degrees flip angle. At each slice position, a total of four images w...

متن کامل

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

Gradient recalled echo MR imaging of the jugular foramen.

Axial T1-weighted spin-echo MR images have not proved to be effective in identifying normal structures in the jugular foramen. By correlating cryomicrotomic sections and axial T1-weighted gradient recalled echo images, we identified the neural and vascular contents of the jugular foramen. Further work with gradient recalled echo images is needed to determine the signal characteristics of jugula...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJR. American journal of roentgenology

دوره 151 5  شماره 

صفحات  -

تاریخ انتشار 1988