Detectability of glaucomatous changes using SAP, FDT, flicker perimetry, and OCT.
نویسندگان
چکیده
PURPOSE To compare the detectability between glaucomatous visual field changes using standard automated perimetry (SAP), frequency doubling technology (FDT), short-wavelength automated perimetry (SWAP), and flicker perimetry and structural changes using optical coherence tomography (OCT). PARTICIPANTS Fifty-nine eyes of fifty-nine patients with open-angle glaucoma, 24 eyes of 24 glaucoma suspects (GSs), and 40 eyes of 40 healthy age-matched subjects. METHODS All subjects underwent Humphrey visual field analyzer II 24-2 full threshold (SAP), Swedish interactive threshold algorithm-SWAP, FDT (30-1, 30-5, 24-2-1, 24-2-5), flicker perimetry on Octopus 311 (4-zone probability 38S), and Stratus OCT [fast retinal nerve fiber layer thickness (NFLT) and fast optic disc]. To evaluate the visual field, FDT and flicker used the number of abnormal points, whereas SAP used mean deviation (MD) and SWAP used both the number of abnormal points and MD. The areas under the receiver operating characteristic curves [area under the curve (AUCs)] and sensitivities at fixed specificities were used to assess the detectability of glaucoma. RESULTS The AUC for FDT 30-1, 30-5, 24-2-1, 24-2-5, flicker perimetry, SWAP (MD), and SWAP (number of abnormal points) were 0.95, 0.94, 0.88, 0.89, 0.99, 0.88, and 0.88 in the early glaucoma group and 0.67, 0.69, 0.65, 0.70, 0.80, 0.64, and 0.66 in the GS group, respectively. In the early glaucoma and GS groups, all OCT parameters had an AUC >0.81 except the disc area parameter. Especially, average NFLT had the highest AUC of 0.94 in the OCT parameters. CONCLUSIONS FDT, SWAP, flicker perimetry, and OCT are all useful methods for discriminating between healthy eyes and eyes with early glaucoma. Among all 10 OCT parameters, NFLT has the highest sensitivity for detecting early glaucomatous changes in GS patients.
منابع مشابه
Detection of psychophysical and structural injury in eyes with glaucomatous optic neuropathy and normal standard automated perimetry.
OBJECTIVE To compare the prevalence of structural and psychophysical abnormalities in normal eyes and eyes with glaucomatous optic neuropathy (GON) and normal standard automated perimetry (SAP). METHODS Complete examination, SAP, short-wavelength automated perimetry (SWAP), frequency doubling technology (FDT), scanning laser polarimetry (GDx-VCC), and optical coherence tomography (OCT) of the...
متن کاملComparison of matrix frequency-doubling technology perimetry and standard automated perimetry in monitoring the development of visual field defects for glaucoma suspect eyes
BACKGROUND Perimetry is indispensable for the clinical management of glaucoma suspects. Our goal is to compare the performance of standard automated perimetry (SAP) and Matrix frequency-doubling technology (FDT) perimetry in monitoring the development of visual field (VF) defects in glaucoma suspect eyes. METHODS Longitudinal data of paired SAP and FDT from 221 eyes of 155 glaucoma suspects e...
متن کاملHeidelberg Retina Tomograph und Papille
PURPOSE: To compare the abilities of scanning laser polarimetry (SLP), optical coherence tomography (OCT), short-wavelength automated perimetry (SWAP), and frequency-doubling technology (FDT) perimetry to discriminate between healthy eyes and those with early glaucoma, classified based on standard automated perimetry (SAP) and optic disc appearance. To determine the agreement among instruments ...
متن کاملVariability components of standard automated perimetry and frequency-doubling technology perimetry.
PURPOSE To evaluate and compare intra- and intertest variability components for both standard automated perimetry (SAP) and frequency-doubling technology (FDT) perimetry in a small group of normal individuals and patients with glaucoma. METHODS The method of constant stimuli (MOCS) was used to examine matched test locations with both SAP and FDT perimetry stimuli in a group of eight normal in...
متن کاملDetecting early glaucoma by assessment of retinal nerve fiber layer thickness and visual function.
PURPOSE To compare the abilities of scanning laser polarimetry (SLP), optical coherence tomography (OCT), short-wavelength automated perimetry (SWAP), and frequency-doubling technology (FDT) perimetry to discriminate between healthy eyes and those with early glaucoma, classified based on standard automated perimetry (SAP) and optic disc appearance. To determine the agreement among instruments f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of glaucoma
دوره 18 2 شماره
صفحات -
تاریخ انتشار 2009