The rapid shallow breathing index as a predictor of successful mechanical ventilation weaning: clinical utility when calculated from ventilator data
نویسندگان
چکیده
OBJECTIVE The use of the rapid shallow breathing index (RSBI) is recommended in ICUs, where it is used as a predictor of mechanical ventilation (MV) weaning success. The aim of this study was to compare the performance of the RSBI calculated by the traditional method (described in 1991) with that of the RSBI calculated directly from MV parameters. METHODS This was a prospective observational study involving patients who had been on MV for more than 24 h and were candidates for weaning. The RSBI was obtained by the same examiner using the two different methods (employing a spirometer and the parameters from the ventilator display) at random. In comparing the values obtained with the two methods, we used the Mann-Whitney test, Pearson's linear correlation test, and Bland-Altman plots. The performance of the methods was compared by evaluation of the areas under the ROC curves. RESULTS Of the 109 selected patients (60 males; mean age, 62 ± 20 years), 65 were successfully weaned, and 36 died. There were statistically significant differences between the two methods for respiratory rate, tidal volume, and RSBI (p < 0.001 for all). However, when the two methods were compared, the concordance and the intra-observer variation coefficient were 0.94 (0.92-0.96) and 11.16%, respectively. The area under the ROC curve was similar for both methods (0.81 ± 0.04 vs. 0.82 ± 0.04; p = 0.935), which is relevant in the context of this study. CONCLUSIONS The satisfactory performance of the RSBI as a predictor of weaning success, regardless of the method employed, demonstrates the utility of the method using the mechanical ventilator.
منابع مشابه
The rapid shallow breathing index as a predictor of successful mechanical ventilation weaning: clinical utility when calculated from ventilator data
1. Curso de Fisioterapia, Programa de Pós-Graduação em Biociências e Reabilitação e Programa de Pós-Graduação em Reabilitação e Inclusão, Centro Universitário Metodista, Instituto Porto Alegre, Porto Alegre (RS) Brasil. 2. Unidad de Medicina Intensiva, Hospital Morales Meseguer, Murcia, España. First, we would like to congratulate Souza et al. for their article entitled “The rapid shallow breat...
متن کاملAssessment of Rapid Shallow Breathing Index as a Predictor for Weaning in Respiratory Care Unit
BACKGROUND At present, air way support plays pivotal role in management of patients in the ICU (Intensive Care Unit) and also RCU (Respiratory Care Unit). Ventilator weaning is an important step in the care of ICU and RCU patients. It is the gradual removal of mechanical ventilatory support. Different predictors are used for initiation of weaning. This study was designed to investigate the rapi...
متن کاملThe Role of Rapid Shallow Breathing Index in Predicting Successful Weaning of Pediatric Patients with Respiratory Failure
Background About 40 to 60% of all patients admitted to pediatric intensive care unitsundergo mechanical ventilation and 10 to 20% will fail to be extubated. We aimed to determine the role of the rapid shallow breathing index (RSBI) in predicting successful weaning of pediatric patients with respiratory failure. Materials and Methods: This cross-sectional study, was performed on 72 mechanical...
متن کاملMaximum inspiratory pressure and rapid shallow breathing index as predictors of successful ventilator weaning
[Purpose] To investigate the predictive value of maximum inspiratory pressure (MIP) and the rapid shallow breathing index (RSBI) in a ventilator weaning protocol and to evaluate the differences between clinical and surgical patients in the intensive care unit. [Subjects and Methods] Patients aged ≥15 years who underwent orotracheal intubation for mechanical ventilation and who met the criteria ...
متن کاملVariation in the rapid shallow breathing index associated with common measurement techniques and conditions.
BACKGROUND The rapid-shallow-breathing index (RSBI) is widely used to evaluate mechanically ventilated patients for weaning and extubation, but it is determined in different clinical centers in a variety of ways, under conditions that are not always comparable. We hypothesized that the value of RSBI may be significantly influenced by common variations in measurement conditions and technique. ...