چکیده

Two 3-D position-sensitive room temperature semiconductor c-ray spectrometers have been built using 1 cm3 cubic CdZnTe crystals. The lateral coordinates of c-ray interaction are obtained from the location of the 11(x)]11(y) pixellated anodes and the depth (z) is obtained from the ratio of the signals coming from the cathode and the anode. Energy spectra from 662keV incident c-rays have been collected from each of the 11 (x)]11 (y)]20 (z) voxels in both of the CdZnTe devices. After corrections for electron trapping, the difference of weighting potentials in 3-D, and for the gain variation of the readout circuitry, energy resolutions of 1.70% (11.3 keV) FWHM and 1.84% (12.2 keV) FWHM were obtained at 662 keV c-ray energy on the first and second detectors, respectively, from the whole bulk for single-pixel events. Possible improvements in the detector performance are discussed. ( 1999 Elsevier Science B.V. All rights reserved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3D position sensitive CdZnTe gamma-ray spectrometers – improved performance with new ASICs

A 3-dimensional position sensitive CdZnTe gamma-ray spectrometer based on VAS3.1/TAT3 ASICs was developed and tested. The 3-D CZT spectrometer employs a 1.5 × 1.5 × 1 cm CdZnTe crystal with 11 by 11 pixelated anodes wire-bonded to the readout electronics. The signals from the anode pixels and the cathode were both read out through the ASICs. The pixel position provides the lateral 2-D coordinat...

متن کامل

Measurement of material uniformity using 3-D position sensitive CdZnTe gamma-ray spectrometers

We present results from two 1 cm3 CdZnTe gamma-ray spectrometers with full 3-D position sensitivity. To our knowledge, these are the "rst reported semiconductor spectrometers that provide independent spectral data for each of over 2000 volume elements. Energy resolutions of 1.5}1.6% FWHM and position resolutions of 0.7]0.7]0.5 mm were obtained at 662 keV gamma-ray energy from the central region...

متن کامل

A Modeling Method to Calibrate the Interaction Depth in 3-D Position Sensitive CdZnTe Gamma-Ray Spectrometers

The gamma ray interaction depth in 3-D position scnsitive CdZnTe dctectors is currently determined by the pulse height ratio ofthe cathode signal to the anode pixel signal (CIA ratio). In expcriments with our 3-D CdZnTe dctectors, thc photopeak area as a fuuction of the CIA ratio deviates from the expected exponential attcnuation with depth. This indicatcs that the CIA ratio is not proportional...

متن کامل

E!ects of charge sharing in 3-D position sensitive CdZnTe gamma-ray spectrometers

Two 3-D position-sensitive semiconductor c-ray spectrometers operable at room temperature, have been fabricated using 1 cm3 cubic CdZnTe crystals. c-Ray spectra have been obtained from 11(x)]11(y)]20(z) voxels, each corresponding to &0.7]0.7]0.5 mm in the detector volume. Individual spectra from each of the 2420 voxels were corrected for electron trapping, di!erences in weighting potentials, an...

متن کامل

Geometrically weighted semiconductor Frisch grid radiation spectrometers

A new detector geometry is described with relatively high gamma ray energy resolution at room temperature. The device uses the geometric weighting effect, the small pixel effect and the Frisch grid effect to produce high gamma ray energy resolution. The design is simple and easy to construct. The device performs as a gamma ray spectrometer without the need for pulse shape rejection or correctio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999