Wall shear stress and flow patterns in the ascending aorta in patients with bicuspid aortic valves differ significantly from tricuspid aortic valves: a prospective study.
نویسندگان
چکیده
AIMS We compared flow and wall shear stress (WSS) patterns in the ascending aorta of individuals with either bicuspid aortic valve (BAV) or tricuspid aortic valve (TAV) using four-dimensional cardiovascular magnetic resonance (4D-CMR). BAV are known to be associated with dilation and dissection of the ascending aorta. However, the cause of vessel disease in patients with BAVs is unknown. Inborn connective tissue disease and also dilation secondary to increased WSS because of altered blood flow patterns in the ascending aorta are discussed as causes for dilation of the aorta. WSS can be estimated non-invasively by 4D-CMR. METHODS AND RESULTS Eighteen, otherwise, healthy individuals with functionally normal BAVs were compared prospectively with an age- and sex-matched control group of healthy individuals with TAV. Blood flow data were obtained by 4D-CMR visualization and WSS was calculated with specific software tools. Eighty-five per cent of the individuals with BAVs showed a high-grade helical flow pattern in the ascending aorta compared with 6% of the individuals with TAV. WSS in the ascending aorta was significantly altered in individuals with BAVs compared with TAV. CONCLUSION WSS and flow patterns in the ascending aorta in patients with BAVs without concomitant valve or vessel disease are significantly different compared with TAV. The significantly higher shear forces may have an impact on the development of aortic dilation in patients with BAVs.
منابع مشابه
Bicuspid aortic valve is associated with altered wall shear stress in the ascending aorta.
BACKGROUND Hemodynamics may play a role contributing to the progression of bicuspid aortic valve (BAV) aortopathy. This study measured the impact of BAV on the distribution of regional aortic wall shear stress (WSS) compared with control cohorts. METHODS AND RESULTS Local WSS distribution was measured in the thoracic aorta of 60 subjects using 4-dimensional (4D) flow-sensitive magnetic resona...
متن کاملGiant saphenous vein graft aneurysm presenting as stridor.
Bicuspid aortic valve configuration and aortopathy pattern might represent different pathophysiologic sub-strates. A, Byers PH et al. The bicuspid aortic valve: an integrated phenotypic classification of leaflet morphology and aortic root shape. Association of Bicuspid aortic valve morphology and aortic root dimensions: a sub-study of the aortic stenosis progression observation measuring effect...
متن کاملAscending Aortic Wall Cohesion: Comparison of Bicuspid and Tricuspid Valves
Objectives. Bicuspid aortic valve (AV) represents the most common form of congenital AV malformation, which is frequently associated with pathologies of the ascending aorta. We compared the mechanical properties of the aortic wall between patients with bicuspid and tricuspid AV using a new custom-made device mimicking transversal aortic wall shear stress. Methods. Between 03/2010 and 07/2011, 1...
متن کاملPhase contrast 4D flow in bicuspid aortic valves in a porcine model
Background Bicuspid aortic valves (BAV) are associated with aneurysms of the ascending aorta (AAA). It is unclear whether these aneurysms are caused by tissue alterations of the aortic wall or by alterations of blood flow in the ascending aorta due to the bicuspid valve morphology. In this study we analyzed the phase contrast 4D flow characteristics in normal tricuspid aortic valves (TAV) in a ...
متن کاملIntraindividual validation of 4D flow measurement against 2D flow measurements in aortas with bicuspid or tricuspid valves by cardiovascular magnetic resonance (CMR)
Background Theoretically, blood flow in the ascending aorta of patients with helical flow patterns, as in patients with bicuspid aortic valves (BAV), are underestimated by routine two dimensional (2D) phase contrast velocity encoding (PC-VENC). Four dimensional (4D) PC-VENC is theoretically not influenced by flow patterns. Hence, both, 2D PC-VENC and 4D PC VENC should result in similar blood fl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European heart journal cardiovascular Imaging
دوره 14 8 شماره
صفحات -
تاریخ انتشار 2013