Photon vs Energy Magnitude Systems and the Measurement of the Cosmological Parameters
نویسندگان
چکیده
The relative brightnesses of standard candles have long been known to be potentially powerful probes of distance. The distance modulus, the difference between observed and absolute magnitudes, has been associated with the values of the cosmological parameters: Hubble’s constant H0, the mass density ΩM and the cosmological constant ΩΛ. In the literature the relationship between these parameters and the distance modulus is calculated for an energy magnitude system; the Johnson-Cousins magnitude system used in observations is in fact a photon-counting system. In this paper, we present the relation between observed and absolute photon magnitudes in terms of the familiar energy distance modulus and derive the correct form of the K-correction. The differences between energy and photon systems are small relative to the measurement errors of contemporary high-redshift supernova searches. The distinction must be made, however, for precision cosmological measurements such as those planned for Type Ia supernovae. Subject headings: Distance scale — supernovae: general
منابع مشابه
Measurement Of Scatter Factors For Small Photon Fields Using Gaf chromic EBT2 Film
Introduction: Small field dosimetry is challenging for radiotherapy dosimetry. measurement of the output factor in the air and water (Sc, Scp) is one of the input parameters for commissioning of treatment planning systems and beam modeling. The aims of this study are to measured Sc,Scp for small fields with EBT2 and Ion chamber and design a appropriate mini-phantom for small fi...
متن کاملInvestigations of parameters affecting the photon energy spectra of an 18 MV Varian 2100C/D linear accelerator
Radiotherapy using linear accelerators is known as an effective modality for cancer treatment. The photons energy of treatment beams significantly affect the dose distribution. Therefore, it is important to accurately evaluate the photon energy spectra. In this study, MCNPX Monte Carlo code (version 2.6.0) was used to simulate an 18 MV photon beam of a Varian 2100C/D linear accelerator. By matc...
متن کاملBenchmarking of Monte Carlo model of 6 Mv photon beam produced by Siemens Oncor® linear accelerator: determination of initial electron beam parameters in comparison with measurement
Introduction: The aim of this study was to investigate the initial electron beam parameters for Monte Carlo model of 6MV photon beam produced by Siemens Oncor® linear accelerator. Materials and Methods: In this study, the EGSnrc Monte Carlo user codes BEAMnrc and DOSXYZnrc were used. The beamnrc code were used for modelling of a 6 MV photon beam produced by...
متن کاملMonte Carlo Modeling of Dual and Triple Photon Energy Absorptiometry Technique
Introduction: Osteoporosis is a bone disease in which there is a reduction in the amount of bone mineral content leading to an increase in the risk of bone fractures. The affected individuals not only have to go through lots of pain and suffering but this disease also results in high economic costs to the society due to a large number of fractures. A timely and accurate diagnosis of this disea...
متن کاملThe effect of high energy photon beam in dose- volume parameters and integral dose of normal structures in Head and neck IMRT
Introduction: The aim of this study is to investigate the effect of partially used high photon energies on dosimetric parameters and integral doses of nasopharynx IMRT plans. Materials and Methods: Two 7 coplanar IMRT plan were created for eleven patients (6 MV only IMRT plan in both phase1 and phase2 and 6 MV phase1-mixed energies (6 MV and 15 MV) phase2...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002