Statistical methods for monitoring the relationship between the IFCC reference measurement procedure for hemoglobin A1c and the designated comparison methods in the United States, Japan, and Sweden.
نویسندگان
چکیده
BACKGROUND The American Diabetes Association (ADA)/European Association for the Study of Diabetes (EASD)/International Diabetes Federation (IDF)/IFCC Consensus Statement on the worldwide standardization of HbA(1c) states that "... [HbA(1c)] results are to be reported world-wide in IFCC units ... and derived NGSP units ... , using the IFCC-NGSP master equation." METHODS We describe statistical methods to evaluate and monitor the relationships as expressed in master equations (MEs) between the IFCC Reference Measurement procedure (IFCC-RM) and designated comparison methods (DCMs) [US National Glycohemoglobin Standardization Program (NGSP), Japanese Diabetes Society/Japanese Society for Clinical Chemistry (JDS/JSCC), and Mono-S in Sweden]. We applied these statistics, including uncertainty calculations, to 12 studies in which networks of reference laboratories participated, operating the IFCC-RM and DCMs. RESULTS For NGSP and Mono-S, slope, intercept, and derived percentage HbA(1c) at the therapeutic target show compliance with the respective MEs in all 12 studies. For JDS/JSCC, a slight deviation is seen in slope and derived percentage HbA(1c) in 2 of the 12 studies. Using the MEs, the uncertainty in an assigned value increases from 0.42 mmol/mol HbA(1c) (IFCC-RM) to 0.47 (NGSP), 0.49 (JDS/JSCC), and 0.51 (Mono-S). CONCLUSIONS We describe sound statistical methods for the investigation of relations between networks of reference laboratories. Application of these statistical methods to the relationship between the IFCC-RM and DCMs in the US, Japan, and Sweden shows that they are suitable for the purpose, and the results support the applicability of the ADA/EASD/IDF/IFCC Consensus Statement on HbA1c measurement.
منابع مشابه
IFCC reference system for measurement of hemoglobin A1c in human blood and the national standardization schemes in the United States, Japan, and Sweden: a method-comparison study.
BACKGROUND The national programs for the harmonization of hemoglobin (Hb)A(1c) measurements in the US [National Glycohemoglobin Standardization Program (NGSP)], Japan [Japanese Diabetes Society (JDS)/Japanese Society of Clinical Chemistry (JSCC)], and Sweden are based on different designated comparison methods (DCMs). The future basis for international standardization will be the reference syst...
متن کاملA review of the challenge in measuring hemoglobin A1c.
The attraction of the simple biochemical concept combined with a clinical requirement for a long-term marker of glycolic control in diabetes has made hemoglobin A1c (HbA1c) one of the most important assays undertaken in the medical laboratory. The diversity in the biochemistry of glycation, clinical requirements, and management demands has resulted in a broad range of methods being developed si...
متن کاملGlobal Harmonization of Hemoglobin A1c
Measurement of glycohemoglobin (GHb) is widely used in patients with diabetes mellitus as a monitor of longterm glycemic control (1–3). In addition, prospective randomized clinical trials, most notably the Diabetes Control and Complications Trial (DCCT) and the United Kingdom Prospective Diabetes Study (UKPDS), have demonstrated that GHb is a measure of the risk for the development of diabetes ...
متن کاملThe IFCC Reference Measurement System for HbA1c: a 6-year progress report.
BACKGROUND The IFCC Reference Measurement System for hemoglobin (Hb)A(1c) (IFCC-RM) has been developed within the framework of metrologic traceability and is embedded in a network of 14 reference laboratories. This paper describes the outcome of 12 intercomparison studies (periodic evaluations to control essential elements of the IFCC-RM). METHODS Each study included: unknown samples (to test...
متن کاملImproved reference measurement method for hemoglobin A1c by use of liquid chromatography-isotope dilution-tandem mass spectrometry.
We have developed an improved reference measurement method for hemoglobin A1c (Hb A1c) 1 based on liquid chromatography–isotope dilution–tandem mass spectrometry (LC-ID-MS/MS) with traceability to the SI unit. The method has a small measurement uncertainty (MU) and gives results in good agreement with the accuracy-based IFCC reference method. Kaiser et al. (1 ) demonstrated the possibility of u...