Demonstrated use of metered-dose inhalers and peak flow meters by children and adolescents with acute asthma exacerbations.

نویسندگان

  • Richard J Scarfone
  • Geoffrey A Capraro
  • Joseph J Zorc
  • Huaqing Zhao
چکیده

OBJECTIVES To determine the ability of children and adolescents with acute asthma exacerbations to adhere to national guidelines for proper metered-dose inhaler (MDI) and peak flow meter (PFM) technique and to define characteristics associated with improper use. DESIGN A prospective study in which the patients were instructed to use a placebo MDI or a PFM in the emergency department exactly as at home. Technique was graded on the basis of performance of specific steps recommended by national guidelines. SETTING AND PARTICIPANTS Children and adolescents (aged 2-18 years) with acute asthma exacerbations in the emergency department of an urban children's hospital with acute asthma. RESULTS Thirty-three (45.2%) of 73 patients using an MDI (MDI group) demonstrated multiple steps improperly compared with 60 (44.4%) of 135 using an MDI with a holding chamber (MDI-HC group; P =.92). In the MDI group, young ages of the patients (P<.008) and the parents (P<.003) were associated with improper use. In the MDI-HC group, factors independently and significantly associated with improper use were no hospitalizations within the past year, parent assistance of the patient with MDI-HC use, and nondaily use of the MDI-HC. Also, 165 (82.9%) of 199 children who, per national guidelines, should be using a PFM at home, did not. Eighty-two (73.9%) of 111 patients demonstrated perfect performance of all PFM steps. CONCLUSIONS Among children with acute asthma, we found high rates of improper MDI use and PFM underuse. A greater emphasis must be placed on teaching methods to optimize drug delivery and to instruct patients about the importance of self-monitoring of disease severity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Usage Pattern, Satisfaction, Causes of Concern and Related Factors of Metered Dose Inhalers in Children with Asthma, the Parents Perspective

Introduction  Metered Dose Inhalers (MDIs) are the most common drugs for the control of asthma. This study was conducted to evaluate usage patterns, satisfaction with and concerns about MDIs for children with asthma and the related factors from the viewpoints’ of their parents. Materials and methods This cross-sectional study was conducted on children with asthma who referred to asthma and a...

متن کامل

Systematic review of clinical effectiveness of pressurised metered dose inhalers versus other hand held inhaler devices for delivering corticosteroids in asthma.

OBJECTIVE To determine the clinical effectiveness of pressurised metered dose inhalers (with or without spacer) compared with other hand held inhaler devices for the delivery of corticosteroids in stable asthma. DESIGN Systematic review of randomised controlled trials. DATA SOURCES Cochrane Airways Group trials database (Medline, Embase, Cochrane controlled clinical trials register, and han...

متن کامل

Incidence of acute decreases in peak expiratory flow following the use of metered-dose inhalers in asthmatic patients.

This study aimed to investigate and compare the incidence of metered-dose inhaler (MDI)-associated bronchoconstriction in an asthmatic population, following the use of three different MDIs. Two different placebo metered-dose inhaler preparations containing the same chlorofluorocarbons but differing in dispersant chemicals, one containing oleic acid (MDI-OA) and the other lecithin NF (MDI-L), we...

متن کامل

An assessment of a new breath actuated inhaler device in acutely wheezy children.

A randomised double blind, two period cross over study was designed to compare the ability of 51 hospitalised asthmatics with acute exacerbations to use each of two inhalers. The inhalers compared were a new breath actuated metered dose inhaler, the Autohaler inhalation device, and a dry powder device, the Rotahaler. Preassessment data included the measurement of peak inspiratory flow rate (PIF...

متن کامل

Efficacy of inhaled corticosteroids in infants and preschoolers with recurrent wheezing and asthma: a systematic review with meta-analysis.

OBJECTIVE To compare the efficacy of inhaled corticosteroids in infants and preschoolers with recurrent wheezing or asthma. METHODS Randomized, prospective, controlled trials published January 1996 to March 2008 with a minimum of 4 weeks of inhaled corticosteroids versus placebo were retrieved through Medline, Embase, and Central databases. The primary outcome was wheezing/asthma exacerbation...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Archives of pediatrics & adolescent medicine

دوره 156 4  شماره 

صفحات  -

تاریخ انتشار 2002