Fresh gas formulae do not accurately predict end-tidal PCO2 in paediatric patients.

نویسندگان

  • J M Badgwell
  • A R Wolf
  • B A McEvedy
  • J Lerman
  • R E Creighton
چکیده

To determine the fresh gas flow (FGF) requirements in paediatric patients, we measured the FGFs needed to maintain distal end-tidal PCO2 (PETCO2) values at 30 and 38 mmHg in patients weighing between 3.8 and 20 kg ventilated with either a Sechrist Infant Ventilator IV-100B or an Air-Shields Ventimeter and a Mapleson D circuit. The FGF requirement was 500 ml.kg-1.min-1 to maintain a PETCO2 of 30 mmHg and 250 ml.kg-1.min-1 to maintain a PETCO2 of 38 mmHg when minute ventilation greater than or equal to FGF. When these formulae were used in a subsequent group of similar patients, a wide variation in PETCO2 measurements were obtained. We conclude that the safest and most accurate approach to determine the FGF requirement of paediatric patients is to continuously monitor the PETCO2 in each patient and to adjust the FGF accordingly.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی همبستگی و میزان توافق نتایج PaCO2 گازهای خون شریانی با CO2 انتهای بازدمی (End-Tidal CO2) توسط کاپنوگرافی در بیماران مبتلا به تشدید حاد بیماری انسدادی ریوی (COPD)

  Background : Chronic Obstructive Pulmonary Disease (COPD) represents a major public health problem. The course of COPD is characterized by episodic periods of worsening symptoms, termed exacerbations. Supplemental oxygen should be given to patients with COPD exacerbation without causing CO2 retention. Arterial blood gas sampling is the gold standard for monitoring adequate oxygenation and for...

متن کامل

Analyser position for end-tidal carbon dioxide monitoring in a rebreather circuit.

INTRODUCTION A diving rebreather currently nearing release incorporates an infra-red CO2 analyser at the end of the exhale hose and uses the expired gas CO2 measurement made at this position to detect hypercapnia. This configuration may allow exhaled anatomic and mouthpiece dead space gas to mix with alveolar gas in the exhale hose thus falsely lowering the CO2 measurement, especially at low ti...

متن کامل

Performance of transcutaneous PO2 and PCO2 dual electrodes in adults.

Three commercially-available combined PO2-PCO2 electrodes were assessed in vitro, and in adults breathing air, hypoxic and hypercapnic mixtures, for speed of response, correlation with end-tidal gas tensions and drift. Differences in the 90% response time of the individual electrodes were more marked in vitro than in vivo. Changes in end-tidal gas tensions were reflected by proportionate change...

متن کامل

Steady-state diffusing capacity determined by a simplified method.

One of the disadvantages of the method of Filley, MacIntosh, and Wright (1954) for determining the steady-state diffusing capacity is that it requires the collection and analysis of arterial blood. This adds materially to the time needed to make the determination. In normal individuals it is possible to use end-tidal Pco2 in place of arterial Pco2, or end-tidal concentration of CO as recommende...

متن کامل

Fresh gas requirements of an enclosed afferent reservoir breathing system during controlled ventilation in children.

An enclosed afferent reservoir breathing system (EAR) designed by Ohmeda was evaluated during anaesthesia with controlled ventilation in 104 healthy children. Carbon dioxide production and arterial carbon dioxide tension were measured in 12 children in order to determine the proportion of fresh gas (VF) involved in gas exchange. When the ratio of minute volume ventilation to fresh gas flow (VE:...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Canadian journal of anaesthesia = Journal canadien d'anesthesie

دوره 35 6  شماره 

صفحات  -

تاریخ انتشار 1988