Physics (CT VI-Cone Beam CT)

نویسندگان

  • Stephen J. Glick
  • Bruce R. Whiting
  • Pengfei Yang
  • Kevin Royalty
  • Charles M. Strother
  • Guang-Hong Chen
چکیده

Participants Kai Niu, MS, Madison, WI (Presenter) Nothing to Disclose Pengfei Yang, Shanghai, China (Abstract Co-Author) Nothing to Disclose Beverly A. Kienitz, MD, DDS, Madison, WI (Abstract Co-Author) Nothing to Disclose Ke Li, PhD, Madison, WI (Abstract Co-Author) Nothing to Disclose Sebastian Schafer, Madison, WI (Abstract Co-Author) Consultant, Siemens AG Kevin Royalty, PhD,MBA, Hoffman Estates, IL (Abstract Co-Author) Employee, Siemens AG Charles M. Strother, MD, Madison, WI (Abstract Co-Author) Research Consultant, Siemens AG Research support, Siemens AG License agreement, Siemens AG Guang-Hong Chen, PhD, Madison, WI (Abstract Co-Author) Research funded, General Electric Company; Research funded, Siemens AG

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the gray level in CBCT systems and its relationship with HU in CT Scanners

Introduction: Cone-beam CT (CBCT) is an imaging system which offers three-dimensional (3D), multiplanar images and has many advantages over computed tomography (CT) including shorter acquisition times for the resolution desired in dentistry, lower radiation dose to the patient, reasonable price and higher spatial resolution but CBCT scanners are unable to display actual Hounsf...

متن کامل

Evaluation of Factors Affecting Absorbed Dose, Optimization Methods and Patient Dose Reduction in Dental Cone Beam CT (CBCT)

Introduction: Nowadays the use of cone beam computed tomography in dental imaging is increasing, although this method has a much lower dose than conventional CT scans, it delivers a higher dose than the panoramic and periapical patients therefore, , the aim of this study was to investigate the factors affecting the patients' dose in dental CBCTs and methods of optimizing and reducing the patien...

متن کامل

The Impact of Residual Geometric Inaccuracies on Normal Organ Doses in Image Guided-Radiation Therapy of Prostate Cancer Using On-Board Kilovoltage Cone-Beam Computed Tomography

Introduction: The aim of this retrospective study was to evaluate the variations in delivered dose to the bladder, rectum, and femoral heads of prostate cancer patients during a course of treatment by image-guided radiation therapy (IGRT). Materials and Methods: Overall, 15 patients with prostate cancer were selected and. Each week, for each patient five consecutive cone beam computed tomograph...

متن کامل

Compensators for dose and scatter management in cone-beam computed tomography.

The ability of compensators (e.g., bow-tie filters) designed for kV cone-beam computed tomography (CT) to reduce both scatter reaching the detector and dose to the patient is investigated. Scattered x rays reaching the detector are widely recognized as one of the most significant challenges to cone-beam CT imaging performance. With cone-beam CT gaining popularity as a method of guiding treatmen...

متن کامل

How does CT image noise affect 3D deformable image registration for image-guided radiotherapy planning?

PURPOSE To measure the sensitivity of deformable image registration to image noise. Deformable image registration can be used to map organ contours and other treatment planning data from one CT to another. These CT studies can be acquired with either conventional fan-beam CT systems or more novel cone-beam CT techniques. However, cone-beam CT images can have higher noise levels than fan-beam CT...

متن کامل

A Grangeat-type half-scan algorithm for cone-beam CT.

Modern CT and micro-CT scanners are rapidly moving from fan-beam toward cone-beam geometry. Half-scan CT algorithms are advantageous in terms of temporal resolution, and widely used in fan-beam and cone-beam geometry. While existing half-scan algorithms for cone-beam CT are in the Feldkamp framework, in this paper we compensate missing data explicitly in the Grangeat framework, and formulate a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -