Periimplant Bone Response in Human-Retrieved, Clinically Stable, Successful, and Functioning Dental Implants After a Long-Term Loading Period: A Report of 17 Cases From 4 to 20 Years.

نویسندگان

  • Giovanna Iezzi
  • Adriano Piattelli
  • Carlo Mangano
  • Marco Degidi
  • Tiziano Testori
  • Giovanni Vantaggiato
  • Elisabetta Fiera
  • Massimo Frosecchi
  • Pierluigi Floris
  • Roberto Perroni
  • Lorenzo Ravera
  • Gerardo Gómez Moreno
  • Emanuele De Martinis
  • Vittoria Perrotti
چکیده

OBJECTIVE This study aimed at a histologic and histomorphometric analysis of the periimplant tissues and bone-titanium interface reactions in successfully osseointegrated, clinically stable, and immobile human titanium dental implants retrieved after a long loading period. MATERIALS AND METHODS In the last 30 months (2013-2015), 21 implants, retrieved from individuals for different causes after a loading period ranging from 4 to 20 years, were sent to the Implant Retrieval Center, University of Chieti-Pescara, Italy. In 4 cases, almost all the bone had been lost during the retrieval, whereas in the remaining 17 cases, mineralized bone was still present. RESULTS Around the majority of the implants, mature compact bone with few marrow spaces was found. The trabecular bone, constituted by a few thin bone trabeculae, was in a periimplant location around only a few implants. A high percentage of bone-implant contact (BIC) (comprised between 32 ± 4.1% and 83 ± 2.9%) was present. In almost all implants, the space within the threads was almost completely filled by compact lamellar bone or by a thin layer of bone. Close and tight contact between bone and implant surface was observed in all specimens with no gaps or connective tissue at the interface. CONCLUSIONS All implants appeared to be well integrated in the surrounding mineralized bone, and all of them showed adequate bone-to-implant contact percentages.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Success rate of immediate loading of single OPILS implants of Neo-Dent system

Success rate of immediate loading of single OPILS implants of Neo-Dent system Dr. SH. Namjoy Nik * - Dr. SH. Shahab ** - Dr. M. Mohammad Poor*** - Dr. A. Balooch*** *- Assistant Professor of Oral and Maxillofacial Surgery Dept. - Faculty of Dentistry – Shahed University. **- Assistant Professor of Oral Radiology Dept. Faculty of Dentistry – Shahed University. ***- Dentist. Background and Aim: I...

متن کامل

Treatment of periimplantitis with an Er: YAG Laser and GBR A case report

Treatment of periimplantitis with an Er: YAG Laser and GBR A case report Dr. M. Rismanchian* - Dr. R. Birang** - Dr. A. Moghareh Abed** *- Assistant Professor of Fixed Prosthodontics Dept. Faculty of Dentistry – Isfahan University of Medical Sciences. **- Assistant Professor of Periodontics Dept. Faculty of Dentistry, Isfahan University of Medical Sciences. Introduction: The increasing use of d...

متن کامل

Immediate loading in dental implants ( A literature review )

Immediate loading in dental implants ( A literature review ) Dr. Seyedan K.,1 Dr. Hafezeqoran A.,2 Dr. Sazgara H.3 1Assistant Professor, Department of Prosthodentists,Dental School Shahid Beheshti University of Medical Sciences,Tehran, Iran.2Dentist, Post Graduate Student, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran-Iran.3Associate Profess...

متن کامل

Determining the prevalence of peri-implantitis in patients one year after prosthetic loading in Khorramabad in 2021

Background and Aims: Although dental implants have become a successful and predictable ong-term treatment for patients, not all implant treatments are necessarily successful and pre-implant diseases are spreading. The aim of this study was to determine the prevalence of peri-implantitis in patients one year after prosthetic loading in Khorramabad in 2021. Materials and Methods: In this cross-s...

متن کامل

Radiographic Comparison of Crestal Bone Loss Around Two Implant Systems with Different Surface Roughness: A Retrospective Study

Background and Aim: This retrospective study aimed to investigate the effects of surface roughness and implant body design on the amount of crestal bone loss around implant. Materials and Methods: In this retrospective study, dental records of 87 patients who received 139 implants were evaluated. The ITI group received 63 implants with moderate roughness, while the DIO group received 76 implan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Implant dentistry

دوره 25 3  شماره 

صفحات  -

تاریخ انتشار 2016