Monitoring micrometer-scale collagen organization in rat-tail tendon upon mechanical strain using second harmonic microscopy.

نویسندگان

  • Y Goulam Houssen
  • I Gusachenko
  • M-C Schanne-Klein
  • J-M Allain
چکیده

We continuously monitored the microstructure of a rat-tail tendon during stretch/relaxation cycles. To that purpose, we implemented a new biomechanical device that combined SHG imaging and mechanical testing modalities. This multi-scale experimental device enabled simultaneous visualization of the collagen crimp morphology at the micrometer scale and measurement of macroscopic strain-stress response. We gradually increased the ultimate strain of the cycles and showed that preconditioning mostly occurs in the first stretching. This is accompanied by an increase of the crimp period in the SHG image. Our results indicate that preconditioning is due to a sliding of microstructures at the scale of a few fibrils and smaller, that changes the resting length of the fascicle. This sliding can reverse on long time scales. These results provide a proof of concept that continuous SHG imaging performed simultaneously with mechanical assay allows analysis of the relationship between macroscopic response and microscopic structure of tissues.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Polarization-resolved second-harmonic generation in tendon upon mechanical stretching.

Collagen is a triple-helical protein that forms various macromolecular organizations in tissues and is responsible for the biomechanical and physical properties of most organs. Second-harmonic generation (SHG) microscopy is a valuable imaging technique to probe collagen fibrillar organization. In this article, we use a multiscale nonlinear optical formalism to bring theoretical evidence that an...

متن کامل

Mechanical characterization of collagen fibers and scaffolds for tissue engineering.

Engineered tissues must utilize scaffolding biomaterials that support desired cellular functions and possess or can develop appropriate mechanical characteristics. This study assessed properties of collagen as a scaffolding biomaterial for ligament replacements. Mechanical properties of extruded bovine achilles tendon collagen fibers were significantly affected by fiber diameter, with smaller f...

متن کامل

Analysis of collagen fiber domain organization by Fourier second harmonic generation microscopy.

We present an automated and systematic two-dimensional discrete Fourier transform (2D-FFT) approach to analyze collagen fiber organization through the use of second harmonic generation (SHG) microscopy. Average orientations of individual domains and Ising-like order parameters introduced to characterize the correlation between orientations of adjacent domains may be used to quantitatively chara...

متن کامل

High-resolution second-harmonic optical coherence tomography of collagen in rat-tail tendon

A high-resolution second-harmonic optical coherence tomography sSH-OCTd system is demonstrated using a spectrum broadened femtosecond Ti:sapphire laser. An axial resolution of 4.2 mm at the second-harmonic wave center wavelength of 400 nm has been achieved. Because the SH-OCT system uses the second-harmonic generation signals that strongly depend on the orientation, polarization, and local symm...

متن کامل

Second harmonic generation analysis of early Achilles tendinosis in response to in vivo mechanical loading

BACKGROUND Tenocytes have been implicated in the development of tendinosis, a chronic condition commonly seen in musculoskeletal overuse syndromes. However, the relation between abnormal tenocyte morphology and early changes in the fibrillar collagen matrix has not been closely examined in vivo. Second harmonic generation (SHG) microscopy is a recently developed technique which allows examinati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomechanics

دوره 44 11  شماره 

صفحات  -

تاریخ انتشار 2011