A glucose oxidase inmobilized electrode based on modified graphite.

نویسندگان

  • Nina Dimcheva
  • Elena Horozova
  • Zinaida Jordanova
چکیده

Glucose oxidase (E. C. 1.1.3.4) was immobilized on electrochemically modified graphite to obtain an enzyme electrode. The working surface of the electrode was coated with gelatine to prevent desorption of the enzyme. In substrate (glucose) solutions the amperometric signal of the enzyme electrode was due to the electroreduction of H202 generated in the enzyme layer. The linearity of the electrode response was found up to a substrate concentration of 300 microM at a working potential of 0 mV (vs. Ag/AgCl). It was shown that the electrode did not respond to L-ascorbic and uric acid at that working potential. The response time was about 2 min. The enzyme electrode keeps about 50% of its initial activity after a one-week storage at 4 degrees C.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A laccase–glucose oxidase biofuel cell prototype operating in a physiological buffer

Here we report on the design and study of a biofuel cell consisting of a glucose oxidase-based anode (Aspergillus niger) and a laccasebased cathode (Trametes versicolor) using osmium-based redox polymers as mediators of the biocatalysts’ electron transfer at graphite electrode surfaces. The graphite electrodes of the device are modified with the deposition and immobilization of the appropriate ...

متن کامل

Non-enzymatic Amperometric Glucose Biosensor Based on Copper Hexacyanoferrate-film Modified-gnp-graphite Composite Electrode

A non-enzymatic amperometric glucose biosensor based on a modified electrode was fabricated by electrochemical derivatization of copper hexacyanoferrate (CuHCF) film at gold nanoparticles (GNP) adsorbed graphite wax composite electrode. The modified electrode was characterized by cyclic voltammetry and electrochemical impedance spectroscopy (EIS). The electrode was also characterized by scannin...

متن کامل

Self-gelatinizable copolymer immobilized glucose biosensor based on prussian blue modified graphite electrode.

A novel poly(vinyl alcohol) grafting 4-vinylpyridine self-gelatinizable copolymer was adapted to immobilize glucose oxidase. The reduction of hydrogen peroxide (H2O2) was detected at a Prussian Blue (PB) modified graphite electrode. A stable and sensitive glucose amperometric biosensor is described. The copolymer is a good biocompatible polymer in which the glucose oxidase retains high activity...

متن کامل

Preserved enzymatic activity of glucose oxidase immobilized on unmodified electrodes for glucose detection.

Glucose sensing electrodes have been realized by immobilizing glucose oxidase (GOx) on unmodified edge plane of highly oriented pyrolytic graphite (epHOPG) and the native oxide of heavily doped silicon (SiO2/Si). Both kinds of electrode show direct interfacial electron transfer due to the redox process of the immobilized GOx. The measured formal potential of the redox process agrees with that o...

متن کامل

Voltammetric determination of amitriptyline based on graphite screen printed electrode modified with a Copper Oxide nanoparticles

A novel electrochemical sensor was proposed for the determination of amitriptyline based on the copper oxide (CuO) nanoparticles modified graphite screen-printed electrode. CuO nanoparticles were used to enhance the surface area of the electrode and then improve the sensitivity of the electrochemical sensor. Amitriptyline electrochemical response characteristics of the modified electrode in a p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Zeitschrift fur Naturforschung. C, Journal of biosciences

دوره 57 7-8  شماره 

صفحات  -

تاریخ انتشار 2002