Coding of electric pulse trains presented through cochlear implants in the auditory midbrain of awake rabbit: comparison with anesthetized preparations.

نویسندگان

  • Yoojin Chung
  • Kenneth E Hancock
  • Sung-Il Nam
  • Bertrand Delgutte
چکیده

Cochlear implant (CI) listeners show limits at high frequencies in tasks involving temporal processing such as rate pitch and interaural time difference discrimination. Similar limits have been observed in neural responses to electric stimulation in animals with CI; however, the upper limit of temporal coding of electric pulse train stimuli in the inferior colliculus (IC) of anesthetized animals is lower than the perceptual limit. We hypothesize that the upper limit of temporal neural coding has been underestimated in previous studies due to the confound of anesthesia. To test this hypothesis, we developed a chronic, awake rabbit preparation for single-unit studies of IC neurons with electric stimulation through CI. Stimuli were periodic trains of biphasic pulses with rates varying from 20 to 1280 pulses per second. We found that IC neurons in awake rabbits showed higher spontaneous activity and greater sustained responses, both excitatory and suppressive, at high pulse rates. Maximum pulse rates that elicited synchronized responses were approximately two times higher in awake rabbits than in earlier studies with anesthetized animals. Here, we demonstrate directly that anesthesia is a major factor underlying these differences by monitoring the responses of single units in one rabbit before and after injection of an ultra-short-acting barbiturate. In general, the physiological rate limits of IC neurons in the awake rabbit are more consistent with the psychophysical limits in human CI subjects compared with limits from anesthetized animals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Auditory nerve fiber responses to electric stimulation: modulated and unmodulated pulse trains.

Many modern cochlear implants use sound processing strategies that stimulate the cochlea with modulated pulse trains. Rubinstein et al. [Hear. Res. 127, 108 (1999)] suggested that representation of the modulator in auditory nerve responses might be improved by the addition of a sustained, high-rate, desynchronizing pulse train (DPT). In addition, activity in response to the DPT may mimic the sp...

متن کامل

Cochlear-implant high pulse rate and narrow electrode configuration impair transmission of temporal information to the auditory cortex.

In the most commonly used cochlear prosthesis systems, temporal features of sound are signaled by amplitude modulation of constant-rate pulse trains. Several convincing arguments predict that speech reception should be optimized by use of pulse rates > or approximately 2,000 pulses per second (pps) and by use of intracochlear electrode configurations that produce restricted current spread (e.g....

متن کامل

Auditory temporal acuity probed with cochlear implant stimulation and cortical recording.

Cochlear implants stimulate the auditory nerve with amplitude-modulated (AM) electric pulse trains. Pulse rates >2,000 pulses per second (pps) have been hypothesized to enhance transmission of temporal information. Recent studies, however, have shown that higher pulse rates impair phase locking to sinusoidal AM in the auditory cortex and impair perceptual modulation detection. Here, we investig...

متن کامل

Comparison of Auditory Perception in Cochlear Implanted Children with and without Additional Disabilities

Background: The number of children with cochlear implants who have other difficulties such as attention deficiency and cerebral palsy has increased dramatically. Despite the need for information on the results of cochlear implantation in this group, the available literature is extremely limited. We, therefore, sought to compare the levels of auditory perception in children with cochlear implant...

متن کامل

Resolution of single deviant intervals in periodic stimuli by auditory cortex neurons: comparison of intracochlear electric pulse and acoustic click stimulation.

Responses of neurons in the primary auditory cortex were compared in gerbils receiving intracochlear electric or acoustic stimulation. Stimuli were trains of periodic electric pulses or of acoustic clicks. Interspersed between intervals of equal length were single intervals which were longer, by some Delta t. The Delta t and the repetition rate of these prolonged intervals were varied. The degr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of neuroscience : the official journal of the Society for Neuroscience

دوره 34 1  شماره 

صفحات  -

تاریخ انتشار 2014