Improvement of defibrillation efficacy and quantification of activation patterns during ventricular fibrillation in a canine heart failure model.
نویسندگان
چکیده
BACKGROUND Little is known about the effects of heart failure (HF) on the defibrillation threshold (DFT) and the characteristics of activation during ventricular fibrillation (VF). METHODS AND RESULTS HF was induced by rapid right ventricular (RV) pacing for at least 3 weeks in 6 dogs. Another 6 dogs served as controls. Catheter defibrillation electrodes were placed in the RV apex, the superior vena cava, and the great cardiac vein (CV). An active can coupled to the superior vena cava electrode served as the return for the RV and CV electrodes. DFTs were determined before and during HF for a shock through the RV electrode with and without a smaller auxiliary shock through the CV electrode. VF activation patterns were recorded in HF and control animals from 21x24 unipolar electrodes spaced 2 mm apart on the ventricular epicardium. Using these recordings, we computed a number of quantitative VF descriptors. DFT was unchanged in the control dogs. DFT energy was increased 79% and 180% (with and without auxiliary shock, respectively) in HF compared with control dogs. During but not before HF, DFT energy was significantly lowered (21%) by addition of the auxiliary shock. The VF descriptors revealed marked VF differences between HF and control dogs. The differences suggest decreased excitability and an increased refractory period during HF. Most, but not all, descriptors indicate that VF was less complex during HF, suggesting that VF complexity is multifactorial and cannot be expressed by a scalar quantity. CONCLUSIONS HF increases the DFT. This is partially reversed by an auxiliary shock. HF markedly changes VF activation patterns.
منابع مشابه
New manifestations of electrophysiological remodeling of heart during experimental model of atrial fibrillation in cirrhotic rat isolated heart
Introduction: The present study is aimed to evaluate electrophysiological remodeling of atrioventricular (AV) node and ventricular conduction during experimental atrial fibrillation (AF) model in isolated heart of cirrhotic rats. Methods: Cirrhosis-induced electrophysiological remodeling was evaluated in 24 isolated retrogradely perfused rat hearts in 2 groups (control and cirrhotic). Cirrho...
متن کاملModulation of extracellular atrioventricular node field potential pattern and ventricular rhythm by morphine in experimental atrial fibrillation in isolated rabbit heart
Introduction: Endorphins are produced by cardiomyocytes, and exert different effects on the heart. The aim of the present study is to assess morphine effects on extracellular atrioventricular (AV) node field potential pattern and ventricular rhythm of isolated rabbit heart during experimental atrial fibrillation (AF). Methods: Effects of different concentrations of morphine (10, 20, 50 and 1...
متن کاملMechanisms of Defibrillation Failure
Since defibrillation by high-energy electric shocks is the only effective means for termination of ventricular fibrillation, defibrillation shocks are now widely used in clinical practice for prevention of sudden cardiac death. However, the high-energy shocks could result in myocardial dysfunction and damage (Runsio et al., 1997) and in psychological trauma (Maisel, 2006). Comprehensive underst...
متن کاملImprovement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization
In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...
متن کاملHypothesis for low-energy transthoracic defibrillation.
timely and informative. The Belfast group has a prodigious experience in out-of-hospital resuscitation and their prospectively collected data have been invaluable in determining energy requirements for defibrillation. The evidence indicating the need for defibrillators storing more than 400 Ws is, at present, inadequate and unconvincing (Lown et al., 1978). In addition to the views expressed by...