Remote robotic navigation and electroanatomical mapping for ablation of atrial fibrillation: considerations for navigation and impact on procedural outcome.
نویسندگان
چکیده
BACKGROUND Radiofrequency current ablation of atrial fibrillation (AF) requires high technical skills to achieve optimal catheter stability and is associated with an individually high x-ray exposure to both the patient and the operator. To facilitate catheter navigation and to reduce the operator's x-ray burden, remote navigation (RN) systems have been developed. Considerations for navigation of a novel remote robotic navigation system in pulmonary vein isolation (PVI) procedures are reported. METHODS AND RESULTS In 65 patients with drug-refractory AF (43 paroxysmal, 22 persistent), complete circumferential PVI was performed using RN in conjunction with different electroanatomic mapping systems. Acute complete PVI using exclusively RN was achieved in 95%. The procedure time was 195+/-40 minutes. The operator's x-ray exposure time was reduced by 6+/-4 minutes (35%) using RN. In 7 of 14 patients with persistent AF, conversion to sinus rhythm was achieved by radiofrequency current ablation. During a median follow-up period of 239 days (range, 184 to 314 days), 47 of 65 patients (73%) remained free of any documented atrial tachyarrhythmia recurrences after a single procedure. The relative proportion of patients remaining free of AF was 76% and 68% for paroxysmal and persistent AF, respectively. CONCLUSIONS PVI using the novel RN system can be performed safely and effectively. One third of the operator's fluoroscopy exposure time might be saved using RN. However, the questions of whether the overall fluoroscopy exposure is reduced by RN and whether RN improves PVI procedures needs to be assessed during a comparative trial between man and machine.
منابع مشابه
Remote Robotic Navigation and Electroanatomical Mapping for Ablation of Atrial Fibrillation – Considerations for Navigation and Impact on Procedural Outcome Short Title: Remote Robotic Navigation for AF Ablation
Background: Radiofrequency current (RFC) ablation of atrial fibrillation (AF) requires high technical skills to achieve optimal catheter stability and is associated with an individually high X-ray exposure to both the patient and the operator. In order to facilitate catheter navigation and to reduce the operator’s X-ray burden remote navigation (RN) systems have been developed. Considerations f...
متن کاملSuccessful ablation of frequent atrial premature beats from non-coronary aortic cusp with remote magnetic navigation
A 59-year-old female with structurally normal heart was admitted to our hospital for treatment of highly symptomatic, drug refractory atrial premature beats (APB). ECG revealed atrial parasystolic trigeminy. The arrhythmogenic focus was mapped and ablated using magnetic remote navigation and 3D electroanatomical mapping system. To our knowledge, this is the first report on successful ablation o...
متن کاملNovel robotic catheter manipulation system integrated with remote magnetic navigation for fully remote ablation of atrial tachyarrhythmias: a two-centre evaluation.
AIMS Studies have shown that remote magnetic navigation is safe and effective for ablation of atrial arrhythmias, although optimal outcomes often require frequent manual manipulation of a circular mapping catheter. The Vdrive robotic system ('Vdrive') was designed for remote navigation of circular mapping catheters to enable a fully remote procedure. This study details the first human clinical ...
متن کاملMapping strategy for multiple atrial tachyarrhythmias in a transplant heart
BACKGROUND Different atrial arrhythmias can coexist in the recipient and donor atria after heart transplantation. CASE PRESENTATION We report an unusual case of a patient with three different types of atrial arrhythmia after heart transplantation: an atrial fibrillation in the recipient atria, and a cavotricuspid isthmus dependent atrial flutter and a focal atrial tachycardia in the donor atr...
متن کاملAtrial Fibrillation Ablation Using Magnetic Navigation Comparison With Conventional Approach During Long-Term Follow-Up.
Atrial fibrillation (AF) ablation targeting the circumferential isolation of pulmonary veins (PVI) is an established therapeutic alternative in symptomatic AF patients resistant to anti-arrhythmic medications. The procedure is technically challenging and multiple difficulties must be overcome in order to achieve a successful outcome. The magnetic navigation system (MNS) is a remote catheter con...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation. Arrhythmia and electrophysiology
دوره 2 2 شماره
صفحات -
تاریخ انتشار 2009