Rapid analysis of polychlorinated biphenyls in the gas phase with resonance-enhanced two-photon ionization: optimal injection of ions into the ion-trap storage/time-of-flight mass spectrometer.

نویسندگان

  • Shinsaku Dobashi
  • Masaharu Kira
  • Ryuichiro Tanaka
  • Yoshinori Izawa
  • Yoshihiro Deguchi
  • Takahiro Kubota
  • Akihide Wada
  • Michikazu Hara
چکیده

LI-IT-TOFMS (laser ionization/ion-trap storage/time-of-flight mass spectrometry) is expected to be a powerful tool for environmental monitoring. In the research reported here, real-time LI-IT-TOFMS measurements were carried out on gaseous 2-4 chlorinated PCBs in order to evaluate the applicability of an environmental monitoring method. With respect to ion-trap storage for PCBs, we found that the effect was due to the driving RF voltage on the ring electrode in the ion trap. For PCBs ions produced by laser irradiation, we observed that it was more efficient to reach the center of the ion trap by using a gated RF voltage rather than by using a continuous RF voltage. The ion trajectories in the ion trap were simulated by SIMION 7.0. We found that the voltage of the exit end cap electrode affected both the number of ions trapped and the orbit of ions inside the trap cell. Optimization of this parameter was performed using both simulated and experimental results. The achievable PCBs sensitivity for real-time (1 min) measurement using the LI-IT-TOFMS method was found to be in the pptV range (<0.01 mg/m3N) by means of a comparison with the conventional gas sampling/GS-MS method. A satisfactory proportional relationship was confirmed between the laser-based and conventional results.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer

A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...

متن کامل

The design and performance of an ion trap storage-reflectron time-of-flight mass spectrometer

The design and performance of an ion trap storage-reflectron time-of-flight mass spectrometer (IT-RETOF MS) combination have been explored for detection of ions generated from both internal and external ionization sources. Ions were generated inside the trap using laser-induced resonance enhanced multiphoton ionization at 266 nm, while ions were generated external to the trap using either an at...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

Real-time monitoring of monochlorinated benzene and polychlorinated biphenyls in the gas phase with on-line detection: High chemical selectivity of resonance-enhanced two-photon ionization.

The development of molecular spectroscopy has enabled us to select chlorinated aromatic hydrocarbons very rapidly. In particular, the laser ionization TOFMS (time-of-flight mass spectrometry) method is expected to be useful as an on-line, selective, and sensitive method. In the present work, real-time laser ionization TOFMS measurements were carried out on gaseous chlorinated aromatic hydrocarb...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 21 9  شماره 

صفحات  -

تاریخ انتشار 2005