Human skin microcirculation after brachial plexus block evaluated by wavelet transform of the laser Doppler flowmetry signal.

نویسندگان

  • Svein A Landsverk
  • Per Kvandal
  • Trygve Kjelstrup
  • Uros Benko
  • Alan Bernjak
  • Aneta Stefanovska
  • Hebe Kvernmo
  • Knut A Kirkeboen
چکیده

BACKGROUND The skin microcirculation may be evaluated noninvasively by laser Doppler flowmetry and iontophoresis with acetylcholine and sodium nitroprusside. Wavelet transform of the perfusion signal shows periodic oscillations of five characteristic frequencies in the interval 0.0095-1.6 Hz. The aim of the current study was to investigate alterations in skin microcirculation induced by brachial plexus block, with emphasis on the periodic oscillations. METHODS Healthy nonsmokers undergoing hand surgery (n = 13) were anesthetized with brachial plexus block, using bupivacaine, lidocaine, and epinephrine. Skin microcirculation was evaluated by laser Doppler flowmetry and iontophoresis with acetylcholine and sodium nitroprusside before and after brachial plexus block. Wavelet transform of the perfusion signal was performed. As a control group, 10 healthy nonsmokers were included. RESULTS In the anesthetized arm, skin perfusion after brachial plexus block increased from 19 (12-30) to 24 (14-39) arbitrary units (P < 0.01). A significant increase was also seen in the contralateral arm from 17 (14-32) to 20 (14-42) arbitrary units (P < 0.01). After brachial plexus block, spectral analysis revealed a significant reduction in relative amplitude of the oscillatory components within the 0.0095- to 0.021- (P < 0.001) and 0.021- to 0.052-Hz (P < 0.001) intervals in the anesthetized arm. CONCLUSION Alterations in skin microcirculation induced by brachial plexus block can be evaluated by wavelet transform of the laser Doppler flowmetry signal. Brachial plexus block reduces the oscillatory components within the 0.0095- to 0.021- and 0.021- to 0.052-Hz intervals of the perfusion signal. These alterations are related to inhibition of sympathetic activity and a possible impairment of endothelial function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of the Wavelet Spectrum of the Oscillations of Basal Blood Flow During Cold Pressor Tests on the Fingers

In the article we evaluated the possibility of using different methods of analysis of signals of laser Doppler flowmetry and tissue reflectance oximetry in the study of oscillations of basal blood flow before and after the cold pressor tests on the fingers. We conducted the experimental study and evaluated the results. The data revealed that the use of spectral analysis and adaptive wavelet tra...

متن کامل

Wavelet-analysis of gastric microcirculation in rats with ulcer bleedings

Nitric oxide (NO) plays an important role in regulation of central and peripheral circulation in normal state and during hemorrhagic stress. Because the impaired gastric mucosal blood flow is the major cause of gastroduodenal lesions including ulcer bleeding (UB), we study in this work the NO-ergic mechanism responsible for regulation of this blood flow. Our study is performed in rats with a mo...

متن کامل

Evaluation of Carpal Tunnel Syndrome by Laser Doppler Flowmetry

Background:Autonomic disturbance can leads to blood flow changes that can be studied by various methods. Objective: To assess the blood flow changes in patients with severe carpal tunnel syndrome  by laser Doppler flowmetry Methods:Ten patients with severe unilateral carpal tunnel syndrome confirmed by electrodiagnostic examination enrolled in this study. Patients comprised one man and nine wom...

متن کامل

Brachial plexus block using lidocaine/ epinephrine or lidocaine/ xylazine in fat-tailed sheep

This blinded, randomized experimental study was designed to evaluate the analgesic effects of adding epinephrine or xylazine to lidocaine solution for brachial plexus block (BPB) in sheep. Nine healthy, fat-tailed female lambs (26.6 ± 1.5 kg) were randomly allocated into three groups: lidocaine 2%, 5 mg kg-1 (LID, n = 6), lidocaine (5 mg kg-1) with epinephrine 5 µg mL...

متن کامل

Wavelet analysis of blood flow dynamics: effect on the individual oscillatory components of iontophoresis with neutral electrolytes

Abstract. Iontophoresis currents are used in the transcutaneous delivery of vasoactive substances for noninvasive assessment of skin vascular properties. The blood flow rate can be recorded by laser Doppler flowmetry (LDF), its average value and the amplitudes of its oscillatory components being used to evaluate the effect of the drugs. Because non-drug-specific, current-induced, vasodilation c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 105 3  شماره 

صفحات  -

تاریخ انتشار 2006