Utility of implantable loop recorder (Reveal Plus) in the diagnosis of unexplained syncope.

نویسندگان

  • Federico Lombardi
  • Ezio Calosso
  • Giosuè Mascioli
  • Egidio Marangoni
  • Andrea Donato
  • Stefano Rossi
  • Massimo Pala
  • Francesco Foti
  • Maurizio Lunati
چکیده

AIMS In about 30% of patients with syncope, the responsible mechanisms remain unrecognised. Nevertheless, the possibility of an arrhythmic aetiology remains, however, difficult to rule out. METHODS We therefore monitored with an implantable loop recorder (ILR, Reveal Plus, Medtronic) 34 subjects (60+/-15 years) with at least two unexplained syncopal episodes and negative neurological and cardiovascular work-up. RESULTS During a follow-up of 7+/-4 months, syncope occurred in 11 subjects. In nine of them the mechanisms responsible for these events were identified by ILR monitoring: marked bradycardia or asystole (n=6), atrial fibrillation with wide QRS tachycardia (n=1) and sinus rhythm with fine artifacts likely to be due to muscle contractions (n=2). Pre-syncope occurred in seven patients: advanced atrioventricular block (n=3), sinus tachycardia (n=1), and wide QRS tachycardia (n=1) were documented. Thus, when considering all 18 patients with recurrences, a diagnosis was achieved in 53% of subjects. Recognition of the rhythm disorder in seven patients with syncope and four patients with pre-syncope guided patient management. CONCLUSIONS These data indicate that ILR monitoring facilitates the identification of mechanisms responsible for recurrences and therapeutic management in subjects with syncope or pre-syncope and negative traditional neurological and cardiovascular work-up.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Implantable Loop Recorder: Current Uses, Future Directions

Implantable loop recorders (ILRs) have evolved as an elegant means of establishing a correlation between symptoms and cardiac rhythm disturbances in patients suffering from recurrent and unexplained episodes of syncope. In this review, we focus on the currently available ILRs on the US market and our institution’s experience with a novel ILR implantation technique. We also review the currently ...

متن کامل

The implantable loop recorder-an important addition to the armentarium in the management of unexplained syncope.

INTRODUCTION Unexplained syncope is a common condition with a significant impact both on the patient and on healthcare expenditure. Often, the diagnosis is hampered due to the temporary sporadic nature of the symptoms. Conventional monitoring methods have a low yield for identifying an abnormality during a spontaneous event. The implantable loop recorder (ILR), often underutilised, is an import...

متن کامل

Implantable Loop Recorder in Diagnosis of Unexplained Syncope

Implantable loop recorder is a diagnostic method in cardiology, having a role in revealing the cause of recurrent unexplained syncope. For automatic recording, the device is equipped with bradycardia and tachycardia programmable options. Battery capacity is 14 months. The aim of the study was to investigate the use of loop recorder in the diagnosis of unexplained syncope. The study enrolled the...

متن کامل

Use of Implantable Loop Recorders to Unravel the Cause of Unexplained Syncope

Syncope is a symptom of many underlying disease states, which range from the relatively benign to the life threatening. There are numerous investigations done for patients with recurrent unexplained syncope which may have very low yield when it comes to making a definitive diagnosis. Recently, the implantable loop recorder (ILR) for continuous monitoring of the cardiac rhythm has been launched ...

متن کامل

Usefulness of an Implantable Loop Recorder in Patients with Syncope of an Unknown Cause

PURPOSE The mechanisms underlying syncope remain unknown in about 20% of patients with recurrent syncope. The implantable loop recorder (ILR) has been shown to be a useful diagnostic tool in patients with unexplained syncope even after negative initial evaluations. Nevertheless, ILR has rarely been used in clinical practice. MATERIALS AND METHODS This study included 18 consecutive patients wh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 7 1  شماره 

صفحات  -

تاریخ انتشار 2005