Bone-resorptive effects of endotoxin-contaminated high-density polyethylene particles spontaneously eliminated in vivo.
نویسندگان
چکیده
Wear particles commonly used for experiments may carry adherent endotoxin on their surfaces, which may be responsible for the observed effects. In this study, we attached titanium plates to the tibiae of 20 rats. After osseointegration, endotoxin-contaminated or uncontaminated high-density-polyethylene (HDPE) particles were applied. Contaminated specimens showed a dramatic resorption of bone after seven days but new bone filled the site again at 21 days. Uncontaminated specimens showed no resorption. In 18 rats we implanted intramuscularly discs of ultra-high-molecular-weight polyethylene (UHMWPE) with baseline or excess contamination of endotoxin. Excess endotoxin disappeared within 24 hours and the amount of endotoxin remained at baseline level (contamination from production). Uncontaminated titanium discs did not adsorb endotoxin in vivo. The endotoxin was measured by analytical chemistry. Locally-applied endotoxin stimulated bone resorption similarly to that in experiments with wear particles. Endotoxin on the surface of implants and particles appeared to be inactivated in situ. A clean implant surface did not adsorb endotoxin. Our results suggest that endotoxin adhering to orthopaedic implants is not a major cause for concern.
منابع مشابه
In vivo response to cross-linked polyethylene and polycarbonate-urethane particles.
This study was undertaken to examine macrophage response to polycarbonate-urethane, a proposed alternative material to polyethylene in acetabular components of total hip arthroplasty. Polyethylene wear debris from total joint replacements has been linked to osteolysis and implant lifespan. It has been shown in vitro, that polyethylene particles cleaned of endotoxin generate less of an inflammat...
متن کاملThe effects of the concentration of high-density polyethylene particles on the bone-implant interface.
We used a rat model in vivo to study the effects of the concentration of polyethylene particles on the bone-implant interface around stable implants in the proximal tibia. Intra-articular injections of 10(4), 10(6) or 10(8) high-density polyethylene (HDPE) particles per joint were given 8, 10 and 12 weeks after surgery. The animals were killed after 14 and 26 weeks and the response at the inter...
متن کاملOn study of X-ray absorption and properties of dispersion of W, MoS2 and B4C particles in high density polyethylene
Shielding radiation from both x-rays and gamma-rays is important for personnel in medical fields e.g. interventional radiology, nuclear power stations, and other inspection facilities where radiation is involved. Lead is known for its effective shielding property against these high energy radiations, however heaviness and toxicity are its main drawback. In this study effectiveness of non-lead p...
متن کاملDesign and fabrication of high density borated polyethylene nanocomposites as a neutron shield
Background: Polyethylene composites including boron can be used as an effective neutron shield. Our investigation focuses on manufacturing borated polyethylene nano-composite. The purpose of this study is to design a radiation shield for use in both neutron and gamma fields. Materials and Methods: Borated polyethylene shields containing 2%, and 5% weight percentage of Boron nano-particles w...
متن کاملGeneration of a large volume of clinically relevant nanometre-sized ultra-high-molecular-weight polyethylene wear particles for cell culture studies
It has recently been shown that the wear of ultra-high-molecular-weight polyethylene in hip and knee prostheses leads to the generation of nanometre-sized particles, in addition to micron-sized particles. The biological activity of nanometre-sized ultra-high-molecular-weight polyethylene wear particles has not, however, previously been studied due to difficulties in generating sufficient volume...