Relationships between inspired oxygen concentration and venous admixture during nitrous oxide-oxygen-halothane anaesthesia.
نویسندگان
چکیده
The inspired oxygen concentration (F/O2) was changed on 43 occasions at about 30-min intervals in 13 patients during artificial ventilation with mixtures of nitrous oxide (N2O), oxygen and halothane. Ventilator settings remained unchanged for each patient and at the end of each period, samples of arterial and central venous blood (and, in six patients, pulmonary arterial blood) and inspired and expired gases were collected. Oxygen tension was measured with a dedicated electrode shown to be unaffected by N2O. Venous admixture (Qva/Qt) was calculated at each F/O2. There was a highly significant correlation between the direction of change of F/O2 and that of Qva/Qt, irrespective of whether F/O2 increased or decreased. In 10 patients, there was a progressive increase in Qva/Qt as F/O2 increased above 40%, and in all patients Qva/Qt on nearly 100% oxygen was greater than that measured at the next lowest concentration (60-80%). These results are at variance with the pattern of behaviour predicted from the "critical Va/Q" theory and support the concept of an oxygen-dependent redistribution of perfusion.
منابع مشابه
Effects of nitrous oxide on respiration during halothane anaesthesia in the dog.
The pattern of ventilation was studied in eight greyhounds anaesthetized with halothane in 50% oxygen with nitrogen and in eight with the same concentration of halothane in 50% oxygen with nitrous oxide. There was a significant reduction in both inspiratory and expiratory times in the animals breathing nitrous oxide and an increase in the negative pressures developed in the obstructed airway du...
متن کاملCirculatory effects of pentazocine and pethidine during general anaesthesia with nitrous oxide, oxygen and halothane.
Pentazocine 30 mg and pethidine 30 mg were given intravenously to two groups of patients receiving general anaesthesia with nitrous oxide, oxygen and halothane. The injections were repeated after 10 minutes. The effects on cardiac output, arterial blood pressure, heart rate and central venous pressure were measured. Both drugs caused a transient fall (approximately 20 per cent) in cardiac outpu...
متن کاملStudies of anaesthesia in relation to hypertension. IV. The effects of artificial ventilation on the circulation and pulmonary gas exchanges.
The cardiovascular responses, ventilation and pulmonary gas exchanges of 8 treated and 6 untreated hypertensive patients were studied during artificial ventilation under nitrous oxide/oxygen/relaxant anaesthesia, with and without halothane (1%). Mean arterial pressure (m.a.p.) fell to 69% and 62% of the awake values in the treated and untreated patients respectively during hypocapnia (mean PaCO...
متن کاملComparison of sevoflurane and halothane for outpatient dental anaesthesia in children.
In a prospective, randomized, double-blind clinical study, we have studied 100 children, aged 2-12 yr, to compare halothane and sevoflurane in outpatient dental anaesthesia. All patients were unpremedicated and received inhalation induction using nitrous oxide in oxygen supplemented with either halothane (maximum inspired concentration 5%) or sevoflurane (maximum inspired concentration 8%). Tim...
متن کاملUse of entonox plus carbon dioxide in the dental surgery.
The introduction of Entonox has made it possible to guarantee full oxygenation of the inspired gas of outpatients having nitrous oxide anaesthesia. The addition of 1-2% halothane enables good conditions to be obtained for minor surgery such as dental extraction. The use of an Entonox mixture containing 7% carbon dioxide to stimulate ventilation in patients receiving anaesthesia with nitrous oxi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British journal of anaesthesia
دوره 57 12 شماره
صفحات -
تاریخ انتشار 1985