Improved B1 Homogeneity and Reduced Transmit Power with 4-channel Regional RF Shimming for Breast Imaging at 3 T

نویسندگان

  • Kosuke Ito
  • Yukio Kaneko
  • Yoshihisa Soutome
  • Masahiro Takizawa
چکیده

Target audience: Researchers and engineers who have interest in RF transmit technology in high field MRI. Purpose: The B1 inhomogeneity is one of the problems for breast imaging at 3 T. Various methods using multiple channel RF transmit coil or using some additional dielectric absorptive material are investigated to overcome this problem [1, 2]. These studies showed the number of channels of RF coil increased the homogeneity of B1 improved [1]. However, the RF transmit power also increased by using RF shimming without using additional passive RF coil in some cases [1]. Recently, regional RF shimming was proposed and evaluated numerically in torso region to improve B1 homogeneity [3]. It showed that spatially asymmetric RF field can be created and the homogeneity of B1 in partial region of interest can be improved when the number of RF transmit channel is equal or higher than 4. In this study, the regional RF shimming using 4-channel RF transmit coil was evaluated both in B1 homogeneity and RF transmit power for breast imaging in vivo at 3 T. The results demonstrate that the 4-channel regional RF shimming has an advantage in improvement of B1 homogeneity and reduction of RF transmit power compared to the QD and conventional volume RF shimming. Materials and Methods: 3-T whole body MRI system equipped with 4-channel RF transmit/receive coil [4] was used for this study. B1 maps for each transmit channel was measured by using multi Td method [5, 6]. Scan parameters of B1 mapping sequence are as follows, FOV =500mm, TR/TE =7.5/1.0ms, slice thickness=10mm, and measurement matrix=64×64×3. FA of pre-pulse was π/2 and Td1/Td2 =20/550ms. Scan time was 3 sec for acquiring B1 maps for 4-channels of RF transmit coil. The B1 homogeneity was evaluated by Usd defined as (standard deviation of B1)/(average of B1). RF shimming parameters (amplitude and phase for each RF transmit channel) were calculated by using steepest descent method to minimize Usd. The Usd in breast region and RF transmit power for the following three transmit modes were compared for 6 healthy volunteers; QD mode: Amplitude of each channel is the same, and phase of each channel was 0, -π/2, π, and π/2, respectively. Volume mode: Calculate RF shimming parameters those minimize Usd of entire region (yellow ROI in Fig. 1). The entire region covered the entire breast and back region along axial plane. Regional mode: Calculate RF shimming parameters those minimize Usd of breast region (red ROI in Fig. 1). The ROI was set lower half of axial plane for all volunteers. Relative RF transmit power of each mode was calculated as square sum of all channel amplitudes relative to that of QD mode. Results and Discussion: Figure 2 shows the B1 maps for each transmit channel. The contribution to B1 in breast region from channel 1 and 4 were smaller than that from channel 2 and 3. Figure 3 shows B1 maps of a volunteer’s breast. B1 maps of breast region by using both RF shimming modes (b, c) were more homogeneous than that by using QD mode (a). The mean and the standard deviation of Usd of 6 volunteer’s in breast region (ROI was defined as same as the partial region shown in Fig. 1) and the relative RF transmit power are shown in the table 1. Usd was improved 26% for the volume mode and 35% for the regional mode from QD mode. The relative RF transmit power was reduce by 18% using the regional mode compared to QD mode. By using the regional mode, B1 of back side was lower than that of breast region, because the homogeneity of B1 in back side does not affect Usd in breast region and the relative transmit power decreased. Figure 4 shows RF shimming parameters for the volume mode and the regional mode of all volunteer in 2D complex plane. The complex RF shimming parameters were calculated as follows: ( ) ( ) ( ) ( ) ch ch ch ch phase sin amplitude ch Im , phase cos amplitude ch Re × = × = .

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Whole Body Transmit Coil Configurations for RF Shimming at 3T

Introduction Whole body MRI at 3T may be impeded by B1 transmit field inhomogeneities caused by the dielectric shortening of the RF wavelength [1]. RF shimming techniques based on parallel transmission [2,3] can strongly improve the image quality in clinical whole body applications [4]. In this context, it is an important question, how the RF shimming performance depends on the chosen coil topo...

متن کامل

Evaluation of a Subject specific dual-transmit approach for improving B1 field homogeneity in cardiovascular magnetic resonance at 3T

BACKGROUND Radiofrequency (RF) shading artifacts degrade image quality while performing cardiovascular magnetic resonance (CMR) at higher field strengths. In this article, we sought to evaluate the effect of local RF (B1 field) shimming by using a dual-source-transmit RF system for cardiac cine imaging and to systematically evaluate the effect of subject body type on the B1 field with and witho...

متن کامل

Gain of Imaging Fidelity by Employing a Higher Number of Independent Transmit Channels Together with Slice-Selective Radio-Frequency (RF) Shimming at 7T

Dielectric resonance effects and radio-frequency (RF) power deposition have become challenging issues for magnetic resonance imaging at ultrahigh-field (UHF) strengths. The use of transmit (Tx) coil arrays with independently-driven RF sources using a parallel transmission system is a promising method for alleviating the resulting RF inhomogeneities. In this study, the effect on homogeneity and ...

متن کامل

B 1 shimming with a standard 2 channel headcoil at 7 T : possibilities & limitations

Purpose: To study the possibilities and limitations of RF phase and amplitude shimming with a standard 2 channel head coil at 7T. Introduction One of the main problems in high field MRI is the reduced SNR and loss in contrast due to inhomogeneous B1 RF transmit fields. Spatial homogeneity is of primary importance for diagnostic imaging. At 3T the homogeneity problem is mainly limited to regions...

متن کامل

Extended RF shimming: Sequence‐level parallel transmission optimization applied to steady‐state free precession MRI of the heart

Cardiac magnetic resonance imaging (MRI) at high field presents challenges because of the high specific absorption rate and significant transmit field (B1+ ) inhomogeneities. Parallel transmission MRI offers the ability to correct for both issues at the level of individual radiofrequency (RF) pulses, but must operate within strict hardware and safety constraints. The constraints are themselves ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013