Foreign body reaction after PLC reconstruction caused by a broken PLLA screw.

نویسندگان

  • Tae-Kwon Kim
  • Tae-Wan Jeong
  • Dae-Hee Lee
چکیده

Foreign body reactions may occur in patients who receive bioabsorbable implants during orthopedic surgery for fractures and ligament repair. The authors describe a 34-year-old man who presented with a palpable tender mass on the lateral aspect of the left knee of 1 month's duration. He underwent posterior cruciate ligament and posterolateral corner reconstruction 3 years earlier. Physical examination showed a 1×1-cm soft, nontender mass without localized warmth on the lateral epicondyle of the distal femur. Magnetic resonance imaging showed a broken screw fragment surrounded by a cyst-like mass. Under general anesthesia, the surgeon excised the screw fragment and the fibrotic mass, enclosing it in the subcutaneous tissue at the lateral epicondyle, the site at which a poly-L-lactic acid bioabsorbable screw had been inserted to fix the graft for posterolateral corner reconstruction. Histologic evaluation showed a foreign body reaction to the degraded screw particles. To the authors' knowledge, this report is the first description of a patient presenting with a delayed foreign body reaction to a broken poly-L-lactic acid bioabsorbable screw at the lateral femoral epicondyle after posterolateral corner reconstruction. Because delayed foreign body reactions can occur at any site of poly-L-lactic acid bioabsorbable screw insertion, care should be taken to avoid screw protrusion during ligament reconstruction because it can lead to screw breakage and delayed foreign body reaction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Poly-L-Lactic Acid and Poly-L-Lactic Acid/Hydroxyapatite Bioabsorbable Screws for Tibial Fixation in ACL Reconstruction: Clinical and Magnetic Resonance Imaging Results

BACKGROUND The purpose of this study was to compare the clinical and radiological results of 2 different tibial fixations performed using bioabsorbable screws with added hydroxyapatite (HA) and pure poly-L-lactic acid (PLLA) screws in anterior cruciate ligament (ACL) reconstruction. METHODS A total of 394 patients who underwent arthroscopic ACL reconstruction between March 2009 and June 2012 ...

متن کامل

Painful pretibial pseudocyst at bioabsorbable interference screw aperture two years after anterior cruciate ligament reconstruction.

We report the case of a patient with a painful subcutaneous nodule, measuring 13 mm × 17 mm, at the pretibial graft aperture site, which presented two years after a successful anterior cruciate ligament reconstruction with an autologous hamstring graft. A bioabsorbable poly-L-lactide interference screw was used for graft fixation at the tibial aperture. The patient underwent surgical excision o...

متن کامل

Reduced bone tunnel enlargement post hamstring ACL reconstruction with poly-L-lactic acid/hydroxyapatite bioabsorbable screws.

Bone tunnel enlargement following anterior cruciate ligament (ACL) reconstruction can complicate revision surgery. This study compared postoperative tibial tunnel widening in patients who underwent arthroscopically assisted, single-incision, four-strand hamstring ACL reconstruction using a poly-L-lactic acid/hydroxyapatite blend (PLLA+HA) bioabsorbable interference screw for tibial fixation, wi...

متن کامل

Treatment of Lateral Tibial Condylar Fractures Using Bioactive, Bioresorbable Forged Composites of Raw Particulate Unsintered Hydroxyapatite/Poly-L-Lactide Screws.

Forged composites of raw particulate unsintered hydroxyapatite/poly-L-lactide (F-u-HA/PLLA) devices possess high mechanical strength, bioactivity, and radio-opacity. The aim of this study was to assess the efficacy of F-u-HA/PLLA screws in the treatment of lateral tibial condylar fractures. From January 2005 to December 2010, a total of 7 patients with displaced closed lateral tibial condylar f...

متن کامل

Bioabsorbable Versus Titanium Screws in Anterior Cruciate Ligament Reconstruction Using Hamstring Autograft: A Prospective, Blinded, Randomized Controlled Trial With 5-Year Follow-up.

BACKGROUND Longer-term results of bioabsorbable screws for anterior cruciate ligament reconstruction (ACLR) have been reported, but results are specific to the exact screw material and design. Titanium and poly-L-lactic acid with hydroxyapatite (PLLA-HA) screw outcomes have been compared only to 2 years. PURPOSE/HYPOTHESIS The purpose of this study was to compare the clinical and radiologic o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 37 12  شماره 

صفحات  -

تاریخ انتشار 2014