Deformation of the Durom Acetabular Component and Its Impact on Tribology in a Cadaveric Model—A Simulator Study

نویسندگان

  • Feng Liu
  • Zhefeng Chen
  • Yanqing Gu
  • Qing Wang
  • Weiding Cui
  • Weimin Fan
چکیده

BACKGROUND Recent studies have shown that the acetabular component frequently becomes deformed during press-fit insertion. The aim of this study was to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the Durom large head metal-on-metal (MOM) total hips in simulators. METHODS Six Durom cups impacted into reamed acetabula of fresh cadavers were used as the experimental group and another 6 size-paired intact Durom cups constituted the control group. All 12 Durom MOM total hips were put through a 3 million cycle (MC) wear test in simulators. RESULTS The 6 cups in the experimental group were all deformed, with a mean deformation of 41.78 ± 8.86 µm. The average volumetric wear rate in the experimental group and in the control group in the first million cycle was 6.65 ± 0.29 mm(3)/MC and 0.89 ± 0.04 mm(3)/MC (t = 48.43, p = 0.000). The ion levels of Cr and Co in the experimental group were also higher than those in the control group before 2.0 MC. However there was no difference in the ion levels between 2.0 and 3.0 MC. CONCLUSIONS This finding implies that the non-modular acetabular component of Durom total hip prosthesis is likely to become deformed during press-fit insertion, and that the deformation will result in increased volumetric wear and increased ion release. CLINICAL RELEVANCE This study was determined to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the prosthesis. Deformation of the cup after implantation increases the wear of MOM bearings and the resulting ion levels. The clinical use of the Durom large head prosthesis should be with great care.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Large-head metal-on-metal total hip arthroplasty using the Durom acetabular component at minimum 1-year interval.

Large-head metal-on-metal total hip arthroplasty represents novel technology, and outcome data are lacking. We prospectively compared the performance of a nonmodular metal-on-metal acetabular component (Durom; Zimmer, Warsaw, IN) with a modular titanium component (Trilogy, Zimmer). All Durom components placed at our institution with minimum 1-year follow up (n = 63) were compared with an age- a...

متن کامل

A retrieval analysis of explanted Durom metal-on-metal hip arthroplasties.

Given the recent reports of high failure rates, an improved understanding of the mechanism of failure of large diameter metal-on-metal hip arthroplasties is essential. We present clinical data and tribological analysis of a consecutive series of 74 failed large diameter metal-on-metal hips, comparing the Durom (Zimmer) with the Birmingham hip resurfacing (BHR) (Smith and Nephew). We retrospecti...

متن کامل

Risk of Spermatic Cord Injury During Anterior Pelvic Ring and Acetabular Surgery: An Anatomical Study

  Background: Anterior pelvic ring surgery includes a variety of plating techniques and insertion of retrograde superior pubic ramus screws. Anterior acetabular surgery also includes fixation through an ilioinguinal or Stoppa approach. These exposures risk injury to the spermatic cord and accompanying genital branch of the genitofemoral nerve. The primary aim of this study was to identify the d...

متن کامل

Inguinal Abnormalities in Male Patients with Acetabular Fractures Treated Using an Ilioinguinal Exposure

Purpose: Surgeons performing an ilioinguinal exposure for acetabular fracture surgery need to be aware of aberrant findings such as inguinal hernias and spermatic cord lesions. The purpose of this study is to report these occurrences in a clinical series of adult males undergoing acetabular fracture fixation and a series of adult male cadavers. The secondary aim is to characterize these abnorma...

متن کامل

Finite element modeling of the human head under baton impact

Purpose: This research will try to predict damage probability and calculate the main stress resulted from baton impacts by finite element (FE) modeling of the human head considering skull texture, brain and cerebrospinal fluid.Materials and Methods: A three dimensional FE model of the skull-brain complex was constructed for simulating the baton impact. The FE analysis was carried out using ANSY...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012