Biomechanical effects of offset placement of dental implants in the edentulous posterior mandible

نویسندگان

  • Yuta Shimura
  • Yuji Sato
  • Noboru Kitagawa
  • Miyuki Omori
چکیده

BACKGROUND Proper implant placement is very important for long-term implant stability. Recently, numerous biomechanical studies have been conducted to clarify the relationship between implant placement and peri-implant stress. The placement of multiple implants in the edentulous posterior mandible has been studied by geometric analysis, three-dimensional finite element analysis (FEA), model experimentation, etc. Offset placement is a technique that reduces peri-implant load. However, few studies have used multiple analyses to clarify the value of the offset placement under identical conditions. The present study aimed to clarify the biomechanical effects of offset placement on the peri-implant bone in edentulous posterior mandibles by comparative investigation using FEA and model experimentation with strain gauges. METHODS Three implants were embedded in an artificial mandible in the parts corresponding to the first premolar, the second premolar, and the first molar. A titanium superstructure was mounted to prepare models (experimental models). Three load points (buccal, central, and lingual) were established on the part of the superstructure corresponding to the first molar. Three types of experimental models, each with a different implant placement, were prepared. In one model, the implants were placed in a straight line; in the other two, the implants in the parts corresponding to the second premolar and the first molar were offset each by a 1-mm increment to the buccal or lingual side. Four strain gauges were applied to the peri-implant bone corresponding to the first molar. The experimental models were imaged by micro-computed tomography (CT), and FEA models were constructed from the CT data. A vertical load of 100 N was applied on the three load points in the experimental models and in the FEA models. The extent of compressed displacement and the strain in the peri-implant bone were compared between the experimental models and the FEA models. RESULTS Both experimental and FEA models suffered the least compressed displacement during central loading in all placements. The greatest stress and compressive strain was on the load side in all types of placements. CONCLUSIONS Offset placement may not necessarily be more biomechanically effective than straight placement in edentulous posterior mandibles.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارزیابی گذشته نگر یک تا شش سال کاربرد ایمپلنت های دندانی ITI با استفاده از معیارهای کلینیکی و رادیوگرافیک

In the past two decades, replacement of the missing teeth with implant borne prosthesis has become a treatment modality, accepted by the scientific community for fully and partially edentulous patients. The aim of the present study is to evaluate retrospectively, 502 ITI dental implants application, in partial and complete edentulous patients, treated in two private centers, based on clinical a...

متن کامل

مقایسه بیومکانیکی ایمپلنت دندانی تیتانیوم خالص با زیرکونیوم -5/2% نایوبیوم پس از کاشت به روش اجزای محدود

Background and Aims: Improving dental implantation conditions in order to reduce the failure is always desirable for researchers. The aim of this study was to compare two different materials of dental implants from the viewpoint of biomechanical effect after placement and loading in the mandible. Materials and Methods: A 3D model of mandible was designed in the MIMICS 10.01 software. Then,...

متن کامل

Evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3D finite element analysis

BACKGROUND Rehabilitation using an implant supported overdenture with two implants inserted in the interforaminal region is the easiest and currently accepted treatment modality to increase prosthetic stabilization and patient satisfaction in edentulous patients. The insertion of implants to the weakend mandibular bone decreases the strength of the bone and may lead to fractures either during o...

متن کامل

تعیین توزیع تنش و کرنش استخوان اطراف ایمپلنت در طرح All-on-4 به روش آنالیز اجزای محدود

Background and Aims: The All-on-4 design with its significant advantages is an appropriate model in reconstruction of edentulous mandible. Evaluation of stress and strain distribution in this model is necessary for better judgment. The purpose of this FEA study was to measure stress and strain distribution on peri-implant bone in All-on-4 design in edentulous mandible. Materials and Methods: Th...

متن کامل

A long-term retrospective analysis of survival rates of implants in the mandible.

PURPOSE To retrospectively analyze the survival rate of endosseous dental implants placed in the edentulous or partially edentulous mandible over a long-term follow-up period of 10 years or more. MATERIALS AND METHODS The charts of patients who underwent mandibular implant placement at a private prosthodontics practice and received follow-up care for 10 years or more were included in this stu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2016