A Novel Phantom-Less Spatial and Temporal Ultrasound Calibration Method

نویسندگان

  • Ali Kamen
  • Frank Sauer
چکیده

This paper introduces a novel method for ultrasound calibration for both spatial and temporal parameters. The main advantage of this method is that it does not require a phantom, which is usually expensive to fabricate. Furthermore, the method does not require extensive image processing. For spatial calibration, we solve an optimization problem established by a set of equations that relate the orientations of a line (i.e., calibration pointer) to the intersection points appearing in the ultrasound image. The line orientation is provided through calibration of both ends of the calibration pointer. Temporal calibration is achieved by processing of the captured pointer orientations and the corresponding image positions of intersection along with the timing information. The effectiveness of the unified method for both spatial and temporal calibration is apparent from the quality of the 3D reconstructions of a known object.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasound calibration framework for the image-guided surgery toolkit (IGSTK)

Registration is a key technology in image-guided navigation systems. By aligning pre-operative images with the intra-operative setting these systems provide visual feedback that improves the physician’s understanding of the spatial relationships between anatomical structures and surgical tools. Most often the alignment is obtained using fiducials. Another option is to replace the use of fiducia...

متن کامل

Real-time freehand 3D ultrasound calibration.

Z-fiducial phantoms allow three-dimensional ultrasound probe calibration with a single B-scan. One of the main difficulties in using this phantom is the need for reliable segmentation of the wires in the ultrasound images, which necessitates manual intervention. In this article, we have shown how we can solve this problem by mounting a thin rubber membrane on top of the phantom. The membrane is...

متن کامل

A Rapid Calibration Method for Registration and 3D Tracking of Ultrasound Images Using Spatial Localizer

Conventional freehand 3D ultrasound (US) is a complex process, involving calibration, scanning, processing, volume reconstruction, and visualization. Prior to calibration, a position sensor is attached to the probe for tagging each image with its position and orientation in space; then calibration process is performed to determine the spatial transformation of the scan plan with respect to the ...

متن کامل

Calibration Algorithm for Freehand Ultrasound

Ultrasound (US) image 3-D calibration for freehand probe is an extremely important technique in computerize 3-D ultrasonic (US image model reconstruction).Calibration is a procedure to calculate the spatial relationship between the US image and the tracker attached to the US probe. In this research, a different cross-string phantom and the corresponding algorithm are presented. The phantom with...

متن کامل

A fully automatic calibration procedure for freehand 3D ultrasound

This paper describes a novel method for calibration of freehand three-dimensional (3D) ultrasound. A position sensor is mounted on a conventional ultrasound probe, thus the set of B-scans can be localized in 3D, and can be compounded into a volume. The calibration process aims at determining the transformation (translations, rotations, scaling) between the coordinates system of images and the c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention

دوره 8 Pt 2  شماره 

صفحات  -

تاریخ انتشار 2005