Computer-Aided Analysis of 64-Slice Coronary Computed Tomography Angiography: a Comparison with Manual Interpretation
نویسندگان
چکیده
Coronary computed tomography angiography (CCTA) is increasingly used for the assessment of coronary heart disease (CHD) in symptomatic patients. Software applications have recently been developed to facilitate efficient and accurate analysis of CCTA. This study aims to evaluate the clinical application of computer-aided diagnosis (CAD) software for the detection of significant coronary stenosis on CCTA in populations with low (8%), moderate (13%), and high (27%) CHD prevalence. A total of 341 consecutive patients underwent 64-slice CCTA at 3 clinical sites in the United States. CAD software performed automatic detection of significant coronary lesions (>50% stenosis). CAD results were then compared to the consensus manual interpretation of 2 imaging experts. Data analysis was conducted for each patient and segment. The CAD had 100% sensitivity per patient across all 3 clinical sites. Specificity in the low, moderate, and high CHD prevalence populations was 64%, 41%, and 38%, respectively. The negative predictive value at the 3 clinical sites was 100%. The positive predictive value was 22%, 21%, and 38% for the low, moderate, and high CHD prevalence populations, respectively. This study demonstrates the utility of CAD software in 3 distinct clinical settings. In a low-prevalence population, such as seen in the emergency department, CAD can be used as a Computer-Aided Simple Triage tool to assist in diagnostic delineation of acute chest pain. In a higher prevalence population, CAD software is useful as an adjunct for both the experienced and inexperienced reader.
منابع مشابه
Application of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study
Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...
متن کاملCoronary Artery Disease Diagnostic Performance of 64- versus 256-Slice Computed Tomography Coronary Angiography Compared with Conventional Coronary Angiography in Patients with Suspected Coronary Artery Disease
Purpose: The newer 256-slice computed tomography coronary angiography (CTCA) has the capability of improving diagnostic performance in the detection of obstructive coronary artery disease (CAD) compared to 64-slice CTCA. The aim of this study was to compare the diagnostic performance of 64versus 256-slice CTCA in two similar populations. Methods: Our study included 120 consecutive patients who ...
متن کاملNon-invasive coronary computed tomographic angiography for patients with suspected coronary artery disease: the Coronary Angiography by Computed Tomography with the Use of a Submillimeter resolution (CACTUS) trial.
BACKGROUND Non-invasive coronary angiography by multislice spiral computed tomography (MSCT) is a promising method for the diagnosis of coronary artery disease (CAD). However, the clinical role of this method has not been established for specific patient cohorts. Therefore, the objective of the current prospective, blinded study was to investigate the diagnostic value of coronary MSCT angiograp...
متن کاملComparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism
Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...
متن کاملNovel 320‐slice multislice CT angiography as a gatekeeper for invasive coronary angiography
The diagnostic accuracy of 64‐slice CTA, currently the most widely used CTA system, has been well established by several multicenter studies [4–6]. In a recent prospective multicenter, multivendor trial by Meijboom and coworkers, high diagnostic accuracy of 64‐slice CTA was observed in the evaluation of 360 symptomatic patients with acute and stable angina [5]. On a per‐patient basis, the sensi...