Reliability of the TekScan MatScan® system for the measurement of postural stability in older people with rheumatoid arthritis
نویسندگان
چکیده
BACKGROUND Postural stability can be measured in clinical and research settings using portable plantar pressure systems. People with rheumatoid arthritis (RA) have decreased postural stability compared to non-RA populations and impaired postural stability is associated with falls in people with RA. The purpose of this study was therefore to investigate the reliability of the TekScan MatScan® system in assessing postural stability in people with RA. METHODS Twenty three participants with RA, mean (SD) age 69.74 (10.1) years, were assessed in barefoot double-limb quiet standing, with eyes open and eyes closed, for antero-posterior and medio-lateral postural sway values. Three repetitions, at a sampling frequency of 40 Hz, were recorded for each test condition to obtain a mean value. Measurements were repeated one hour later. Intraclass correlation coefficients (ICC) with 95% confidence intervals (CI) were calculated to determine between-session reliability. Measurement error was assessed through the calculation of the standard error of the measurement (SEM) and the smallest real difference (SRD). RESULTS The system displayed good to excellent reliability for antero-posterior and medio-lateral sway, with eyes open and closed, as indicated by ICC values ranging from 0.84 to 0.92. Measurement error, as evidenced by the SEM, ranged from 1.27 to 2.35 mm. The degree of change required to exceed the expected trial to trial variability was relatively high, compared to mean values, with SRD ranging from 3.08 to 5.71 mm. CONCLUSIONS The portability and ease of use of the TekScan MatScan® makes it a useful tool for the measurement of postural stability in clinical and research settings. The TekScan MatScan® system can reliably measure double-limb quiet standing in older people, aged 60 to 80 years, with RA.
منابع مشابه
Author's response to reviews Title: Reliability of the TekScan MatScan(R) system for the measurement of postural stability in older people with rheumatoid arthritis Authors:
In the background section the authors mention ‘...compared to healthy controls...’ and this may confuse readers in thinking that normal data would be collected and reiterated to further correlated with existing data. The authors should perhaps reword this sentence for absolute clarity. Response: The term “healthy controls” replaced with “non-RA populations” to avoid misleading the reader into t...
متن کاملTest-retest reliability and minimal detectable change for center of pressure measures of postural stability in elderly subjects
Abstract Background: Postural instability has been identified as a potential precursor of falls in elderly subjects. Postural stability in quiet stance is commonly assessed with center of pressure (COP) measures. The purpose of this study was to determine testretest reliability and minimal detectable change (MDC) for the center of pressure (COP) measures in the elderly subjects. Met...
متن کاملReliability of the TekScan MatScan® system for the measurement of plantar forces and pressures during barefoot level walking in healthy adults
BACKGROUND Plantar pressure systems are increasingly being used to evaluate foot function in both research settings and in clinical practice. The purpose of this study was to investigate the reliability of the TekScan MatScan(R) system in assessing plantar forces and pressures during barefoot level walking. METHODS Thirty participants were assessed for the reliability of measurements taken on...
متن کاملTest-Retest Reliability of Dynamic Postural Stability Measures in Healthy and Chronic Non-specific Low Back Pain Groups
Objective: The primary aim of the present study was to study the reliability of postural stability measures during whole body dynamic conditions, so they can be used in postural stability evaluations, investigations of injury mechanisms and assessments of treatment efficacy. Materials & Methods: Twelve healthy volunteers and 12 low back pain patients performed repeated trunk bending motions ...
متن کاملMatrix-mini-tablets of lornoxicam for targeting early morning peak symptoms of rheumatoid arthritis
Objective(s): The aim of present research was to develop matrix-mini-tablets of lornoxicam filled in capsule for targeting early morning peak symptoms of rheumatoid arthritis. Materials and Methods:Matrix-mini-tablets of lornoxicam were prepared by direct compression method using microsomal enzyme dependent and pH-sensitive polymers which were further filled into an empty HPMC capsule. To asses...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 5 شماره
صفحات -
تاریخ انتشار 2012