Improved Spatial Resolution and Reduction of Artifacts in Strain-Maps with Phase-Unwrap HARP
نویسندگان
چکیده
HARP-images of each harmonic peak. The phase is distorted due to B0-inhomogeneity, e.g. in the liver. d) (=b+c) B0-map. e) (=bd/2) Peak-combined HARP-image: Phase wraps of B0-map are present, impairing HARP-analysis. f) Unwrapped B0-map. g) (=b-f/2) Peak-combined HARP-image: No phase distortions (wraps aligned with taglines) and no phase-wraps from B0-map. h) Fully unwrapped peak-combined HARPimage. i) Masked image showing the difference between the original phase of the landmark point (blue ‘x’) and the phase value at each pixel in the new time frame. The starting point of the HARP-search is moved from the blue to the red ‘x’).
منابع مشابه
Artifacts reduction in strain maps of tagged magnetic resonance imaging using harmonic phase
Tagged Magnetic Resonance Imaging (MRI) is a noninvasive technique for examining myocardial function and deformation. Tagged MRI can also be used in quasi-static MR elastography to acquire strain maps of other biological soft tissues. Harmonic phase (HARP) provides automatic and rapid analysis of tagged MR images for the quantification and visualization of myocardial strain. We propose a new ar...
متن کاملInvestigation of the Spatial Resolution and Field of View with Change of Magnification in VRX CT
Introduction: Variable resolution x-ray (VRX) CT is a new type of CT that can image objects at various spatial resolutions. In a VRX CT scanner, the spatial resolution increases at the cost of reduction in the field of view (FOV). An important factor that limits the spatial resolution of the VRX CT is the effect of focal spot size. Also, the optimum magnification is different at each incident a...
متن کاملArtifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملDark-field electron holography for strain and composition measurement with a sub-nanometre spatial resolution
Transmission electron microscopy (TEM) is a well-established tool for strain measurement that combines an excellent precision with a high spatial resolution. Strain maps can be obtained by different TEM techniques such as high-resolution transmission electron microscopy (HRTEM), high-resolution scanning transmission electron microscopy (HR-STEM), convergent beam electron diffraction, nanobeam e...
متن کاملOptimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system
Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...